Korean
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Methods 2020-Aug

A banana peel/silicon glue coated stir bar for extraction of aspirin, diclofenac, ibuprofen and mefenamic acid followed by high performance liquid chromatography-UV detection

등록 된 사용자 만 기사를 번역 할 수 있습니다.
로그인 / 가입
링크가 클립 보드에 저장됩니다.
Zahra Jafari
Mohammad Hadjmohammadi

키워드

요약

In the current study, a green, cost-effective, and bio-degradable additive was used for the preparation of a highly efficient sorbent based on silicon glue. Here, a banana peel was pretreated and mixed with silicon glue. It was proved that the prepared banana peel-silicon glue bar is a reliable sorbent for stir bar sorptive extraction of nonsteroidal anti-inflammatory drugs (NSAIDs) including aspirin, diclofenac, ibuprofen and mefenamic acid in human urine and plasma. Compared to the lab-made sorbents, the prepared sorbent showed high extraction performance, high stability, and satisfactory reproducibility and involved easy preparation. In order to optimize the effective factors, different parameters such as (stirring rate, pH, extraction time, desorption time and elution solvent volume) were optimized using response surface methodology (RSM) through applying Central-Composite Design (CCD). Under the optimum conditions, the linear dynamic ranges of the target analytes were investigated in the range of 0.2-200 μg L-1 with r2 higher than 0.9929. Limits of detection (LODs) and limits of quantification (LOQs) of analytes were in the ranges of 0.04-0.5 and 0.15-1.65, respectively. The reproducibility of the method was also investigated by calculating the relative standard deviation. The RSD was measured to be lower than 4.9%. Bar-to-bar reproducibility at a 100 μg L-1 concentration level was also evaluated to be lower than 5.3% (n = 3). Also, each prepared film can be used up to 64 times without any reduction in extraction performance. Finally, the method was successfully applied for the determination of selected drugs in different biological fluids including urine and plasma samples. The calculated relative recovery in real sample analysis was higher than 90%.

페이스 북
페이지에 가입하세요

과학이 뒷받침하는 가장 완벽한 약초 데이터베이스

  • 55 개 언어로 작동
  • 과학이 뒷받침하는 약초 치료제
  • 이미지로 허브 인식
  • 인터랙티브 GPS지도-위치에 허브 태그 지정 (출시 예정)
  • 검색과 관련된 과학 출판물 읽기
  • 효과로 약초 검색
  • 관심사를 정리하고 뉴스 연구, 임상 실험 및 특허를 통해 최신 정보를 확인하세요.

증상이나 질병을 입력하고 도움이 될 수있는 약초에 대해 읽고 약초를 입력하고 사용되는 질병과 증상을 확인합니다.
* 모든 정보는 발표 된 과학 연구를 기반으로합니다.

Google Play badgeApp Store badge