Lithuanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Artificial Organs 1999-Mar

A preliminary study of microcapsule suspension for hemolysis evaluation of artificial organs.

Straipsnius versti gali tik registruoti vartotojai
Prisijungti Registracija
Nuoroda įrašoma į mainų sritį
O Maruyama
T Yamane
N Tsunemoto
M Nishida
T Tsutsui
T Jikuya

Raktažodžiai

Santrauka

A microcapsule suspension, a substitute for animal blood in hemolysis tests, has been developed for evaluation of the absolute hemolytic properties of circulatory artificial organs. The microcapsule suspension was made by dispersing microcapsule slurry into an ethylene glycol sodium chloride solution. The microcapsule slurry was composed of a leuco dye solution and polyurethane membrane made by the reaction between aliphatic poly-isocyanate and polyamine by interfacial polycondensation. The microcapsule was a small particle containing dye inside. The microcapsule suspension was white; the diameter of the microcapsules was from 5 to 100 microns. The specific gravity of the suspension was 1.024, and the membrane was elastic. The fluid showed Newtonian characteristics, different from animal blood, and its viscosity was approximately 5.8 mPa.s. After the microcapsules were destroyed, the leuco dye was extracted with n-hexane from the suspension and was measured by spectroscopy after being colored with acid ethanol. Hemolysis can be regarded as a fatigue fracture of cell membranes rather than a static fracture. The destruction of microcapsules by a Potter type tissue grinder was observed at a low stroke number region and was compared to rat blood. Moreover, hemolysis tests of a commercially available centrifugal blood pump and the prototype of our centrifugal pump for mechanism checks were carried out with bovine blood. The hemolysis level of the prototype pump increased with time while the hemolysis level of the commercial blood pump did not change as much as that of the control when both pumps were tested with the microcapsule suspension. These results are similar to tests utilizing bovine blood. Therefore, hemolysis tests of circulatory artificial organs completed with microcapsule suspension are expected to provide results similar to tests with animal blood.

Prisijunkite prie mūsų
„Facebook“ puslapio

Išsamiausia vaistinių žolelių duomenų bazė, paremta mokslu

  • Dirba 55 kalbomis
  • Žolelių gydymas, paremtas mokslu
  • Vaistažolių atpažinimas pagal vaizdą
  • Interaktyvus GPS žemėlapis - pažymėkite vaistažoles vietoje (netrukus)
  • Skaitykite mokslines publikacijas, susijusias su jūsų paieška
  • Ieškokite vaistinių žolelių pagal jų poveikį
  • Susitvarkykite savo interesus ir sekite naujienas, klinikinius tyrimus ir patentus

Įveskite simptomą ar ligą ir perskaitykite apie žoleles, kurios gali padėti, įveskite žolę ir pamatykite ligas bei simptomus, nuo kurių ji naudojama.
* Visa informacija pagrįsta paskelbtais moksliniais tyrimais

Google Play badgeApp Store badge