Journal of Adhesive Dentistry 2009-Oct

Effect of different cavity disinfectants on shear bond strength of composite resin to dentin.

Straipsnius versti gali tik registruoti vartotojai
Prisijungti Registracija
Nuoroda įrašoma į mainų sritį
Ertugrul Ercan
Ali Erdemir
Yahya Orcun Zorba
Ayce Unverdi Eldeniz
Mehmet Dalli
Bayram Ince
Baris Kalaycioglu

Raktažodžiai

Santrauka

OBJECTIVE

The aim of this study was to evaluate the effect of different cavity disinfectants on dentin bond strengths of composite resin applied with two different adhesive systems.

METHODS

One hundred mandibular third molars were sectioned parallel to the occlusal surface to expose midcoronal dentin. The dentin surfaces were polished with waterproof-polishing papers. The specimens were randomly divided into 5 groups of 20 each. In group 1, the specimens were not treated with any cavity disinfectants and served as control. From groups 2 to 5, dentin surfaces were treated with the following cavity disinfectants, respectively; 2% chlorhexidine solution, 2.5% NaOCl, 1% chlorhexidine gel, 3% H2O2. The specimens were then randomly divided into 2 subgroups including ten teeth each to evaluate the effect of different bonding systems. Dentin bonding systems were applied to the dentin surfaces and the composite buildups were created. After the specimens were stored in an incubator for 24 h, the shear bond strength was measured at a crosshead speed of 1 mm/min. The bond strength data were analyzed with one way analysis of variance and Tukey-HSD tests.

RESULTS

There was no significant difference between chlorhexidine gel and control groups regardless of the type of the bonding agent (p > 0.05). On the other hand, pretreatment with NaOCl, H2O2 or chlorhexidine solutions had a negative effect on the shear bond strength of self-etching bonding systems.

CONCLUSIONS

The findings of this study suggest that when NaOCl, H2O2 or chlorhexidine solution are used as a cavity disinfectant, an etch-and-rinse bonding system should be preferred.

Prisijunkite prie mūsų
„Facebook“ puslapio

Išsamiausia vaistinių žolelių duomenų bazė, paremta mokslu

  • Dirba 55 kalbomis
  • Žolelių gydymas, paremtas mokslu
  • Vaistažolių atpažinimas pagal vaizdą
  • Interaktyvus GPS žemėlapis - pažymėkite vaistažoles vietoje (netrukus)
  • Skaitykite mokslines publikacijas, susijusias su jūsų paieška
  • Ieškokite vaistinių žolelių pagal jų poveikį
  • Susitvarkykite savo interesus ir sekite naujienas, klinikinius tyrimus ir patentus

Įveskite simptomą ar ligą ir perskaitykite apie žoleles, kurios gali padėti, įveskite žolę ir pamatykite ligas bei simptomus, nuo kurių ji naudojama.
* Visa informacija pagrįsta paskelbtais moksliniais tyrimais

Google Play badgeApp Store badge