Lithuanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Chest 2003-Mar

Effects of chronic intermittent asphyxia on rat diaphragm and limb muscle contractility.

Straipsnius versti gali tik registruoti vartotojai
Prisijungti Registracija
Nuoroda įrašoma į mainų sritį
Michelle McGuire
Mary MacDermott
Aidan Bradford

Raktažodžiai

Santrauka

OBJECTIVE

In obstructive sleep apnea (OSA), there is intermittent upper airway (UA) collapse due to an imbalance between the collapsing force generated by the diaphragm and the stabilizing force of the UA muscles. This results in chronic intermittent asphyxia (CIA). We have previously shown that CIA affects UA muscle fatigue, but little is known about the effects of chronic hypoxia on diaphragm or on limb muscle contractile properties and structure.

METHODS

Rats were exposed to asphyxia and normoxia twice per minute for 8 h/d for 5 weeks to simulate the intermittent asphyxia of OSA in humans. Isometric contractile properties were determined from strips of isolated diaphragm, extensor digitorum longus (EDL), and soleus muscles in Krebs solution at 30 degrees C. EDL and soleus type 1 (slow, fatigue resistant), type 2A (fast, fatigue resistant), and type 2B (fast, fatigable) fiber distribution was determined using adenosine triphosphatase staining.

RESULTS

CIA caused a significant increase in diaphragm, EDL, and soleus fatigue, and reduced recovery from fatigue. Most of the other contractile properties were unaffected aside from a small reduction in diaphragm half-relaxation time and EDL twitch tension and a small shift to the left in the EDL force-frequency curve. There was no change in soleus fiber-type distribution and a small increase in EDL type 2A fibers (46.1 +/- 1.2% vs 49.9 +/- 1.4%, control vs CIA [mean +/- SD]).

CONCLUSIONS

CIA increases diaphragm, EDL, and soleus muscle fatigue. We speculate that if this also occurs in OSA, it would contribute to the pathophysiology of the condition.

Prisijunkite prie mūsų
„Facebook“ puslapio

Išsamiausia vaistinių žolelių duomenų bazė, paremta mokslu

  • Dirba 55 kalbomis
  • Žolelių gydymas, paremtas mokslu
  • Vaistažolių atpažinimas pagal vaizdą
  • Interaktyvus GPS žemėlapis - pažymėkite vaistažoles vietoje (netrukus)
  • Skaitykite mokslines publikacijas, susijusias su jūsų paieška
  • Ieškokite vaistinių žolelių pagal jų poveikį
  • Susitvarkykite savo interesus ir sekite naujienas, klinikinius tyrimus ir patentus

Įveskite simptomą ar ligą ir perskaitykite apie žoleles, kurios gali padėti, įveskite žolę ir pamatykite ligas bei simptomus, nuo kurių ji naudojama.
* Visa informacija pagrįsta paskelbtais moksliniais tyrimais

Google Play badgeApp Store badge