Lithuanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
JACC: Cardiovascular Interventions 2016-Jul

Predictors of Early (1-Week) Outcomes Following Left Atrial Appendage Closure With Amplatzer Devices.

Straipsnius versti gali tik registruoti vartotojai
Prisijungti Registracija
Nuoroda įrašoma į mainų sritį
Konstantinos C Koskinas
Samera Shakir
Máté Fankhauser
Fabian Nietlispach
Adrian Attinger-Toller
Aris Moschovitis
Peter Wenaweser
Thomas Pilgrim
Stefan Stortecky
Fabien Praz

Raktažodžiai

Santrauka

The aim of this study was to assess predictors of adverse 1-week outcomes and determine the effect of left atrial appendage (LAA) morphology following LAA closure (LAAC) with Amplatzer devices.

Percutaneous LAAC is a valuable treatment option for stroke prevention in patients with atrial fibrillation. Determinants of procedural safety events with Amplatzer occluders are not well established, and the possibly interrelating effect of LAA anatomy is unknown.

Between 2009 and 2014, 500 consecutive patients with atrial fibrillation ineligible or at high risk for oral anticoagulation underwent LAAC using Amplatzer devices. Procedure- and device-related major adverse events (MAEs) were defined as the composite of death, stroke, major or life-threatening bleeding, serious pericardial effusion, device embolization, major access-site vascular complication, or need for cardiovascular surgery within 7 days following the intervention.

Patients (mean age 73.9 ± 10.1 years) were treated with Amplatzer Cardiac Plug (n = 408 [82%]) or Amulet (n = 92 [18%]) devices. Early procedural success was 97.8%, and MAEs occurred in 29 patients (5.8%). Independent predictors of MAEs included device repositioning (odds ratio: 9.13; 95% confidence interval: 2.85 to 33.54; p < 0.001) and left ventricular ejection fraction <30% (odds ratio: 4.08; 95% confidence interval: 1.49 to 11.20; p = 0.006), with no effect of device type or size. Angiographic LAA morphology, characterized as cauliflower (33%), cactus (32%), windsock (20%), or chicken wing (15%), was not associated with procedural success (p = 0.51) or the occurrence of MAEs (p = 0.78).

In this nonrandomized study, procedural success of LAAC using Amplatzer devices was high. MAEs within 7 days were predicted by patient- and procedure-related factors. Although LAA morphology displayed substantial heterogeneity, outcomes were comparable across the spectrum of LAA anatomies.

Prisijunkite prie mūsų
„Facebook“ puslapio

Išsamiausia vaistinių žolelių duomenų bazė, paremta mokslu

  • Dirba 55 kalbomis
  • Žolelių gydymas, paremtas mokslu
  • Vaistažolių atpažinimas pagal vaizdą
  • Interaktyvus GPS žemėlapis - pažymėkite vaistažoles vietoje (netrukus)
  • Skaitykite mokslines publikacijas, susijusias su jūsų paieška
  • Ieškokite vaistinių žolelių pagal jų poveikį
  • Susitvarkykite savo interesus ir sekite naujienas, klinikinius tyrimus ir patentus

Įveskite simptomą ar ligą ir perskaitykite apie žoleles, kurios gali padėti, įveskite žolę ir pamatykite ligas bei simptomus, nuo kurių ji naudojama.
* Visa informacija pagrįsta paskelbtais moksliniais tyrimais

Google Play badgeApp Store badge