Latvian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 2015-Jan

A novel method for the simultaneous analysis of seven biothiols in rice (Oryza sativa L.) using hydrophilic interaction chromatography coupled with electrospray tandem mass spectrometry.

Rakstu tulkošanu var veikt tikai reģistrēti lietotāji
Ielogoties Reģistrēties
Saite tiek saglabāta starpliktuvē
Zhao-Yun Cao
Li-Hua Sun
Ren-Xiang Mou
Rong Zhou
Zhi-Wei Zhu
Ming-Xue Chen

Atslēgvārdi

Abstrakts

Analysis of biothiols is still problematic, due to their high polarity, oxidation sensitivity and time-consuming sample preparation. In this paper, a direct, rapid and sensitive method was developed for simultaneous quantification of unbound cysteine (Cys), glutathione (GSH) and phytochelatins (PCs) in rice leaf, stem and root samples by hydrophilic interaction chromatography coupled with electrospray tandem mass spectrometry (HILIC-MS/MS). Homogenized samples were extracted with water containing 50mM dithiothreitol, without derivatization and further clean-up, and the extracts were injected directly onto an Xbridge Amide-HILIC column (3.5μm, 150mm×2.1mm i.d.). The best chromatographic separation and MS sensitivity was achieved using a linear gradient elution with 10mM aqueous ammonium formate and acetonitrile as the mobile phase. In MS/MS mode the detection limit (S/N≥3) of seven biothiols was 3-105nM. Good linearities were observed (r>0.995) with linear dynamic range at least over three orders of magnitude. Recoveries for most analytes were within the range of 77-128%, with relative standard deviations less than 18.2%. The intra-day precision (n=7) was 6.1-11.7%, and the inter-day precision over 15 d (n=15) was 8.5-16.3% for all biothiols. The optimized HILIC-MS/MS method was applied to study the influence of different cadmium (Cd) concentrations (0, 1 and 50μM) on contents of Cys, GSH and PC2-6 in rice tissue. With increasing Cd concentrations in nutrient solutions, contents of PC2-4 in rice roots increased but contents of Cys and GSH decreased. Contents of PC2-4 in both rice leafs and stems increased markedly at high dose Cd (50μM) treatment compared with controls, compared with low Cd concentrations (1μM). However, both PC5 and PC6 were not detected throughout the stress experiment.

Pievienojieties mūsu
facebook lapai

Vispilnīgākā ārstniecības augu datu bāze, kuru atbalsta zinātne

  • Darbojas 55 valodās
  • Zāļu ārstniecības līdzekļi, kurus atbalsta zinātne
  • Garšaugu atpazīšana pēc attēla
  • Interaktīva GPS karte - atzīmējiet garšaugus atrašanās vietā (drīzumā)
  • Lasiet zinātniskās publikācijas, kas saistītas ar jūsu meklēšanu
  • Meklēt ārstniecības augus pēc to iedarbības
  • Organizējiet savas intereses un sekojiet līdzi jaunumiem, klīniskajiem izmēģinājumiem un patentiem

Ierakstiet simptomu vai slimību un izlasiet par garšaugiem, kas varētu palīdzēt, ierakstiet zāli un redziet slimības un simptomus, pret kuriem tā tiek lietota.
* Visa informācija ir balstīta uz publicētiem zinātniskiem pētījumiem

Google Play badgeApp Store badge