Thoracic and Cardiovascular Surgeon 2006-Jun

C1-INH and its effect on infarct size and ventricular function in an acute pig model of infarction, cardiopulmonary bypass, and reperfusion.

Rakstu tulkošanu var veikt tikai reģistrēti lietotāji
Ielogoties Reģistrēties
Saite tiek saglabāta starpliktuvē
C Schreiber
W Heimisch
H Schad
A Brkic
C Badiu
R Lange
R Bauernschmitt

Atslēgvārdi

Abstrakts

BACKGROUND

Recent studies suggest that complement inhibition reduces reperfusion injury. A clinical setting with local application of a C1 esterase inhibitor (C1-INH) has been modeled in an animal study in order to further investigate these findings.

METHODS

In 21 pigs, the left anterior descending coronary artery (LAD) was occluded distally to the first diagonal branch for 2 hours (h), including 1 h of cardioplegic arrest during CPB. After release of the coronary snare, C1-INH or NaCl (control) was applied to the aortic root. Thereafter, the aortic cross-clamp was removed and the heart was reperfused for 30 minutes before weaning from CPB. Left ventricular pressure volume analysis was performed by a multielectrode conductance catheter and the area at risk and infarct size were determined from excised hearts.

RESULTS

The following data were observed (mean+/-SEM) for the control group and the C1-INH group, respectively, after 1-h ligation of the LAD: heart rate (HR) 86+/-3 and 93+/-6 beats/min, stroke volume (SV) 1.2+/-0.1 and 1.2+/-0.1 ml/kg, aortic pressure (AoP) 83+/-6 and 87+/-5 mmHg, left ventricular end-diastolic pressure (LVedP) 12+/-1 and 11+/-2 mmHg; two hours after weaning from CPB: HR 106+/-9 and 123+/-4 beats/min, SV 0.9+/-0.1 and 0.9+/-0.1 ml/kg, AoP 65+/-5 and 79+/-7 mmHg, LVedP 9+/-1 and 8+/-1 mmHg. Conductance catheter measurements showed no improved left ventricular performance after C1-INH application. Infarct size to area at risk ratio was 61.5+/-4.2% for controls and 61.4+/-4.8% for C1-INH.

CONCLUSIONS

Intracoronary application of complement inhibitor in an acute infarction model, which mimicked a clinical setting of urgent coronary bypass grafting after ischemia, has been shown to neither influence the area of infarction, nor the ventricular function.

Pievienojieties mūsu
facebook lapai

Vispilnīgākā ārstniecības augu datu bāze, kuru atbalsta zinātne

  • Darbojas 55 valodās
  • Zāļu ārstniecības līdzekļi, kurus atbalsta zinātne
  • Garšaugu atpazīšana pēc attēla
  • Interaktīva GPS karte - atzīmējiet garšaugus atrašanās vietā (drīzumā)
  • Lasiet zinātniskās publikācijas, kas saistītas ar jūsu meklēšanu
  • Meklēt ārstniecības augus pēc to iedarbības
  • Organizējiet savas intereses un sekojiet līdzi jaunumiem, klīniskajiem izmēģinājumiem un patentiem

Ierakstiet simptomu vai slimību un izlasiet par garšaugiem, kas varētu palīdzēt, ierakstiet zāli un redziet slimības un simptomus, pret kuriem tā tiek lietota.
* Visa informācija ir balstīta uz publicētiem zinātniskiem pētījumiem

Google Play badgeApp Store badge