Macedonian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Virological Methods 1989-Mar

Application of peroxidase labelled antibody assays for detection of porcine IgG antibodies to hog cholera and bovine viral diarrhea viruses.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Врската е зачувана во таблата со исечоци
A Afshar
G C Dulac
A Bouffard

Клучни зборови

Апстракт

Rapid, sensitive peroxidase labelled antibody (PLA) assays using microtiter systems, were developed for detection of hog cholera virus (HCV) and cross-reacting bovine viral diarrhea virus (BVDV) antibodies in pig sera. HCV-infected pig kidney cell line (PK 15) prepared in microtiter plates were fixed and used in PLA assays. After inoculation with test serum, bound antibodies (HCV/BVDV) were reacted with either horseradish peroxidase (HRP) conjugated anti-porcine immunoglobulin (H & L) or biotinylated protein A (BPA) and subsequent HRP labelled avidin (A). Positive reactions were easily visualized under an inverted light microscope as foci of brown colored cells after enzyme degradation of hydrogen peroxidase in the presence of amino-ethylcarbazole (AEC). The PLA assays were superior to the indirect fluorescent antibody (IFA) test in detecting anti-HCV antibodies in porcine sera collected early after inoculation of pigs with a lapinized HCV vaccine. The performances of the PLA, IFA and FA neutralization (FAN) tests in measuring the immune response in the vaccinated pigs were comparable. Cross-reacting anti-BVDV antibody, as measured by a microtiter serum neutralization (MTSN) test, was not demonstrable in vaccinated pigs until they were challenged with a virulent HCV, 13 weeks later. The PLA assays relative to the IFA test detected more reactive samples among porcine field sera collected from HC-free pigs in Canada. Of 795 samples, 24 (3.01%) were reactive in the PLA employing HRP anti-porcine IgG, and 21 (2.6%) in the PLA, using BPA-HRP-A. When 324 of these sera were screened by the IFA test (using HC antigen), only one sample (0.30%) was found reactive.(ABSTRACT TRUNCATED AT 250 WORDS)

Придружете се на нашата
страница на Facebook

Најкомплетната база на податоци за лековити билки поддржана од науката

  • Работи на 55 јазици
  • Лекови од билки поддржани од науката
  • Препознавање на билки по слика
  • Интерактивна GPS мапа - означете ги билките на локацијата (наскоро)
  • Прочитајте научни публикации поврзани со вашето пребарување
  • Пребарувајте лековити билки според нивните ефекти
  • Организирајте ги вашите интереси и останете во тек со истражувањето на новостите, клиничките испитувања и патентите

Напишете симптом или болест и прочитајте за билки што можат да помогнат, напишете билка и видете болести и симптоми против кои се користи.
* Сите информации се базираат на објавени научни истражувања

Google Play badgeApp Store badge