Macedonian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Prosthetic Dentistry 2005-Nov

In vitro wear resistance of three types of composite resin denture teeth.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Врската е зачувана во таблата со исечоци
Jianyu Zeng
Yohei Sato
Chikahiro Ohkubo
Toshio Hosoi

Клучни зборови

Апстракт

BACKGROUND

The wear resistance of artificial teeth is important to the life of the removable prosthesis for the edentulous patient. The ability of artificial teeth to maintain a stable occlusal relationship over time may be influenced by this property.

OBJECTIVE

The purpose of this in vitro study was to evaluate the wear resistance of artificial teeth based on composite resin filler content when opposed by a denture tooth antagonist.

METHODS

The right first molars (both maxillary and mandibular) of 3 composite resin denture teeth (Endura, 47% organic filler; Duradent, 42% organic and inorganic filler; and Duracross, 68% organic filler) were secured in an in vitro 2-body wear-testing apparatus that simulated masticatory function (60 strokes/min, grinding distance of 2 mm, under 37 degrees C flowing water). Wear resistance was assessed as volume loss (mm3) and height loss (mm) at 5 kgf (grinding force) after 50,000 strokes (6 pairs for each type). The Vickers microhardness (VHN) of the occlusal surfaces was measured with a load of 50 g and a loading time of 30 seconds. After testing, the worn surfaces were observed with a scanning electron microscope (SEM). Mean values were analyzed using a 1-way analysis of variance followed by the Fisher test (alpha=.05).

RESULTS

The volume loss of Duradent teeth (0.87 +/- 0.03 mm3) was significantly higher than of the 2 other types of teeth tested (P<.001). The Duracross teeth (0.22 +/- 0.08 mm3 and 0.11 +/- 0.04 mm) exhibited the best wear resistance of the denture teeth tested. The wear resistance of the materials tested was consistent with their hardness (Endura 27.54 +/- 0.67 VHN, Duradent 24.00 +/- 0.60 VHN, Duracross 39.64 +/- 3.11 VHN). SEM observation showed that many filler particles were missing from the matrix of Duradent.

CONCLUSIONS

The wear resistance among the 3 types of teeth was significantly different; Duracross and Endura were more wear resistant than Duradent. Although the densities as reported by the manufacturer were similar, hardness and microstructure were the primary factors affecting the wear resistance of artificial teeth. Hardness appears to correlate with wear resistance since the wear resistance of Duradent with a lower VHN of 24 was greater than the other 2 types of teeth with greater hardness.

Придружете се на нашата
страница на Facebook

Најкомплетната база на податоци за лековити билки поддржана од науката

  • Работи на 55 јазици
  • Лекови од билки поддржани од науката
  • Препознавање на билки по слика
  • Интерактивна GPS мапа - означете ги билките на локацијата (наскоро)
  • Прочитајте научни публикации поврзани со вашето пребарување
  • Пребарувајте лековити билки според нивните ефекти
  • Организирајте ги вашите интереси и останете во тек со истражувањето на новостите, клиничките испитувања и патентите

Напишете симптом или болест и прочитајте за билки што можат да помогнат, напишете билка и видете болести и симптоми против кои се користи.
* Сите информации се базираат на објавени научни истражувања

Google Play badgeApp Store badge