Chest 2010-Feb

Interactions of airflow oscillation, tracheal inclination, and mucus elasticity significantly improve simulated cough clearance.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Врската е зачувана во таблата со исечоци
Anpalaki J Ragavan
Cahit A Evrensel
Peter Krumpe

Клучни зборови

Апстракт

BACKGROUND

Viscoelastic properties of simulated mucus, angle of tracheal inclination (theta), and high-frequency airflow oscillations on median displacement of simulated mucus during simulated cough were investigated in this study.

METHODS

Mucus simulants with viscoelastic properties similar to healthy individuals and patients with COPD were prepared using locust bean gum (LBG)-water solution (0.38 g LBG in 100 mL water) cross-linked with 3-mL and 12-mL borax-water solution (0.02 M), respectively. Aliquots of 0.3 mL of simulants were placed on a dry Plexiglas insert inside a D-shaped clear Plexiglas tracheal model. Movement of aliquots of mucus simulants was measured during cough of 0.3 s duration. Cough velocities studied (5-30 m/s) are typical of patients with weak expiratory muscles and airway obstruction. Studies were conducted with tracheal model placed horizontally (0 degrees) and at increasing theta (15 degrees, 30 degrees, and 45 degrees), with and without superimposed airflow oscillations during coughs. Effects of different parameters and their interactions on displacements of aliquots were compared using analysis of covariance (n = 849).

RESULTS

Significant positive nonlinear associations existed between displacement and cough velocity for both 3-mL and 12-mL simulants (P < .0001). Displacement was greatest for the cohesive 12-mL simulant at all cough velocities. Displacement increased significantly (P < .0001) as theta was increased for both types of simulants. Largest displacements at low cough velocities occurred with 12-mL simulant in the presence of oscillations at 45 degrees angle.

CONCLUSIONS

Results support the use of airflow oscillations and sitting upright to facilitate mucus displacement during cough, particularly with thick, elastic mucus found in patients with COPD (P < .0001).

Придружете се на нашата
страница на Facebook

Најкомплетната база на податоци за лековити билки поддржана од науката

  • Работи на 55 јазици
  • Лекови од билки поддржани од науката
  • Препознавање на билки по слика
  • Интерактивна GPS мапа - означете ги билките на локацијата (наскоро)
  • Прочитајте научни публикации поврзани со вашето пребарување
  • Пребарувајте лековити билки според нивните ефекти
  • Организирајте ги вашите интереси и останете во тек со истражувањето на новостите, клиничките испитувања и патентите

Напишете симптом или болест и прочитајте за билки што можат да помогнат, напишете билка и видете болести и симптоми против кои се користи.
* Сите информации се базираат на објавени научни истражувања

Google Play badgeApp Store badge