Macedonian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American Journal of Physiology - Endocrinology and Metabolism 2005-Aug

Measurement of exogenous carbohydrate oxidation: a comparison of [U-14C]glucose and [U-13C]glucose tracers.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Врската е зачувана во таблата со исечоци
L Moseley
R L P G Jentjens
R H Waring
R M Harris
L K Harding
A E Jeukendrup

Клучни зборови

Апстракт

The purpose of this study was to assess the level of agreement between two techniques commonly used to measure exogenous carbohydrate oxidation (CHO(EXO)). To accomplish this, seven healthy male subjects (24 +/- 3 yr, 74.8 +/- 2.1 kg, V(O2(max)) 62 +/- 4 ml x kg(-1) x min(-1)) exercised at 50% of their peak power for 120 min on two occasions. During these exercise bouts, subjects ingested a solution containing either 144 g glucose (8.7% wt/vol glucose) or water. The glucose solution contained trace amounts of both [U-13C]glucose and [U-14C]glucose to allow CHO(EXO) to be quantified simultaneously. The water trial was used to correct for background 13C enrichment. 13C appearance in the expired air was measured using isotope ratio mass spectrometry, whereas 14C appearance was quantified by trapping expired CO(2) in solution (using hyamine hydroxide) and adding a scintillator before counting radioactivity. CHO(EXO) measured with [13C]glucose ([13C]CHO(EXO)) was significantly greater than CHO(EXO) measured with [14C]glucose ([14C]CHO(EXO)) from 30 to 120 min. There was a 15 +/- 4% difference between [13C]CHO(EXO) and [14C]CHO(EXO) such that the absolute difference increased with the magnitude of CHO(EXO). Further investigations suggest that the difference is not because of losses of CO2 from the trapping solution before counting or an underestimation of the "strength" of the trapping solution. Previous research suggests that the degree of isotopic fractionation is small (S. C. Kalhan, S. M. Savin, and P. A. Adam. J Lab Clin Med89: 285-294, 1977). Therefore, the explanation for the discrepancy in calculated CHO(EXO) remains to be fully understood.

Придружете се на нашата
страница на Facebook

Најкомплетната база на податоци за лековити билки поддржана од науката

  • Работи на 55 јазици
  • Лекови од билки поддржани од науката
  • Препознавање на билки по слика
  • Интерактивна GPS мапа - означете ги билките на локацијата (наскоро)
  • Прочитајте научни публикации поврзани со вашето пребарување
  • Пребарувајте лековити билки според нивните ефекти
  • Организирајте ги вашите интереси и останете во тек со истражувањето на новостите, клиничките испитувања и патентите

Напишете симптом или болест и прочитајте за билки што можат да помогнат, напишете билка и видете болести и симптоми против кои се користи.
* Сите информации се базираат на објавени научни истражувања

Google Play badgeApp Store badge