Steroids 2020-Feb

Detection and quantitation of ecdysterone in human serum by liquid chromatography coupled to tandem mass spectrometry.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Врската е зачувана во таблата со исечоци
Gabriella Ambrosio
Jan Joseph
Bernhard Wuest
Monica Mazzarino
Xavier de la Torre
Patrick Diel
Francesco Botrè
Maria Parr

Клучни зборови

Апстракт

The polyhydroxylated phytosteroid ecdysterone is present in various plants (e.g. spinach). It is widely marketed as the active component of dietary supplements, due to its reported health and performance promoting effects. For evaluation of its actual bioavailability, a fast and sensitive method was developed, optimized and validated for human serum. Instrumental analysis was performed utilizing liquid chromatography-tandem mass spectrometry with positive electrospray ionization and acquisition in multiple reaction mode. Solid phase extraction and dilute-and-inject (following protein precipitation) were tested to isolate ecdysterone from human serum. Both methods were compared in the light of the preset analytical target profile. The limit of detection (LOD) and quantification (LOQ) for ecdysterone in human serum after SPE extraction corresponded to 0.06 ng/mL and 0.14 ng/mL, respectively, meeting the requested sensitivity of the method. The assay was linear over the range from 0.10 ng/mL to 20.83 ng/mL. As expected, the sensitivity of the SPE method was better than that of the dilute-and-inject procedure, which did not allow for quantification of all post administration serum samples. Accuracy (relative error; %) and precision (coefficient of variation; %), were both within acceptance criteria (<15%). The developed method was successfully applied to a ten week intervention study conducted in young men performing regular resistance training. Different doses of supplements containing ecdysterone from spinach extract have been administered during the study and the quantitation of ecdysterone in serum samples has been successfully conducted. Ecdysterone could be quantified in all post-administration samples using solid phase extraction (SPE) for sample pretreatment.

Придружете се на нашата
страница на Facebook

Најкомплетната база на податоци за лековити билки поддржана од науката

  • Работи на 55 јазици
  • Лекови од билки поддржани од науката
  • Препознавање на билки по слика
  • Интерактивна GPS мапа - означете ги билките на локацијата (наскоро)
  • Прочитајте научни публикации поврзани со вашето пребарување
  • Пребарувајте лековити билки според нивните ефекти
  • Организирајте ги вашите интереси и останете во тек со истражувањето на новостите, клиничките испитувања и патентите

Напишете симптом или болест и прочитајте за билки што можат да помогнат, напишете билка и видете болести и симптоми против кои се користи.
* Сите информации се базираат на објавени научни истражувања

Google Play badgeApp Store badge