Macedonian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

lens/hypoxia

Врската е зачувана во таблата со исечоци
Страница 1 од 282 резултати

Hypoxia and contact lens wear.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се

Pseudomonas keratitis and contact lens wear: the lens/eye is at fault.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Microbial keratitis with Pseudomonas aeruginosa is the most common corneal infection associated with contact lenses (CLs). Pseudomonas organisms are ubiquitous in nature, and can colonize CLs without a prior breach in lens care or hygiene. Although poor lens care is often found in affected patients,

Is the lens canned?

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
The ocular lens somehow remains pellucid despite bombardment by ultraviolet radiation and endogenous hydrogen peroxide (present in the humoral fluids which bathe this tissue). The lens and adjacent aqueous and vitreous humors contain exceptionally high concentrations of reducing substances,

Age-dependent control of lens growth by hypoxia.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
OBJECTIVE The lens grows continuously throughout life, but the factors that influence the size of the adult lens are not known. Lens thickness is a significant risk factor for age-related cataract. It has been postulated that the hypoxic environment in the eye protects the lens from nuclear

Hypoxia-regulated activity of PKCepsilon in the lens.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
OBJECTIVE To show that hypoxia is necessary to prevent opacification of the lens. Protein kinase C (PKC)-epsilon serves a role that is distinct from PKC-gamma when both PKC isoforms are expressed in the lens. PKCepsilon serves a very important role in hypoxic conditions, helping to prevent

Corneal hypoxia and hypercapnia during contact lens wear.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Restriction of both oxygen influx to the cornea and carbon dioxide efflux from the cornea by contact lenses results in adverse tissue changes. We measured the extent of hypoxia and hypercapnia at the corneal surface of 10 human volunteers during static, dynamic (blinking), and closed-eye wear of

Contact lens induced corneal acidosis.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
OBJECTIVE Changes in pH in the corneal epithelium, stroma, endothelium and aqueous humor following contact lens wear were evaluated. METHODS Intracellular pH, stromal pH, and aqueous humor pH were measured either in vivo or in vitro in humans and in rabbits using pH-sensitive fluorescent dyes.

Corneal responses to lens transmissibility.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
BACKGROUND Lens transmissibility (Dk/L) and corneal relief from hypoxia are not linearly related. We describe graphically and by equations the relationship between corneal relief (scaled in oxygen shortfall units) and Dk/L across the transmissibility range of 1.2 to 189 x 10(-9) (cm/sec)(ml O2/ml

Soft contact lens wear at altitude: effects of hypoxia.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
In the U.S. Air Force, aircraft can be divided into two categories--those with cabin pressures equivalent to high altitudes and aircraft with cabin pressures equivalent to lower altitudes, with longer duration exposures. The purpose of this study was to determine the effects of soft contact lens

Biochmical aspects of contact lens wear.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Glycogen, adenosine triphosphate, and hydration were measured in rabbit corneal epithelium to determine whether the corneal epithelium glycogen decrease, increase in epithelial hydration, and decrease in epithelial adenosine triphosphate stores, seen as a result of contact lens wear, were secondary

Noninflammatory silicone hydrogel contact lens complications.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
High Dk silicone hydrogel lenses have overcome many of the hypoxic problems associated with traditional extended wear, and the popularity of continuous wear with these lens types is increasing. Despite the elimination of hypoxia, several noninflammatory clinical complications have been reported to

Contact lens wear and microbial keratitis.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Common types of contact lens are hard, rigid gas-permeable or soft lenses. Most lenses are worn on a daily basis. Cosmetic lenses are worn for non-medical indications. Microbial keratitis, a rare but most significant complication is discussed in this article. Pseudomonas aeruginosa and staphylococci

Hydrogel contact lens-induced corneal warpage.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
BACKGROUND Although contact lens-induced corneal warpage is most frequently associated with PMMA lenses, approximately 27% of reported cases of corneal warpage have been attributed to hydrogel lens wear. The change in corneal contour may be the result of either mechanical deformation, chronic

The corneal contact lens and aqueous humor hypoxia in cats.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
The cornea normally receives its oxygen from both the atmosphere and the aqueous humor. When a thick polymethylmethacrylate contact lens is placed on the cat cornea, access of atmospheric oxygen to the cornea is restricted, and the outer part of the cornea becomes hypoxic. This results in an

Are hypoxia or modulus causes of contact lens-associated keratitis?

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Придружете се на нашата
страница на Facebook

Најкомплетната база на податоци за лековити билки поддржана од науката

  • Работи на 55 јазици
  • Лекови од билки поддржани од науката
  • Препознавање на билки по слика
  • Интерактивна GPS мапа - означете ги билките на локацијата (наскоро)
  • Прочитајте научни публикации поврзани со вашето пребарување
  • Пребарувајте лековити билки според нивните ефекти
  • Организирајте ги вашите интереси и останете во тек со истражувањето на новостите, клиничките испитувања и патентите

Напишете симптом или болест и прочитајте за билки што можат да помогнат, напишете билка и видете болести и симптоми против кои се користи.
* Сите информации се базираат на објавени научни истражувања

Google Play badgeApp Store badge