Mongolian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Chemistry 2015-Oct

Electrochemical aptasensor of cardiac troponin I for the early diagnosis of acute myocardial infarction.

Зөвхөн бүртгэлтэй хэрэглэгчид л нийтлэл орчуулах боломжтой
Нэвтрэх / Бүртгүүлэх
Холбоосыг санах ойд хадгалдаг
Hunho Jo
Hyunwoo Gu
Weejeong Jeon
Hyungjun Youn
Jin Her
Seong-Kyeong Kim
Jeongbong Lee
Jae Ho Shin
Changill Ban

Түлхүүр үгс

Хураангуй

Cardiac troponin I (cTnI) is well-known as a promising biomarker for the early diagnosis of acute myocardial infarction (AMI). In this work, single-stranded DNA aptamers against cTnI were identified by the Systematic Evolution of Ligands by Exponential enrichment (SELEX) method. The aptamer candidates exhibited a high selectivity and sensitivity toward both cTnI and the cardiac Troponin complex. The binding affinities of each aptamer were evaluated based on their dissociation constants (Kd) by surface plasma resonance. The Tro4 aptamer that had the highest binding capacity to cTnI showed a very low Kd value (270 pM) compared with that of a cTnI antibody (20.8 nM). Furthermore, we designed a new electrochemical aptasensor based on square wave voltammetry using ferrocene-modified silica nanoparticles. The developed aptasensor demonstrated an excellent analytical performance for cTnI with a wide linear range of 1-10 000 pM in a buffer and a detection limit of 1.0 pM (24 pg/mL; S/N = 3), which was noticeably lower than the cutoff values (70-400 pg/mL). The specificity of the aptamers was also examined using nontarget proteins, demonstrating that the proposed sensor responded to only cTnI. In addition, cTnI was successfully detected in a human serum albumin solution. On the basis of the calibration curve that was constructed, the concentrations of cTnI in a solution supplemented with human serum were effectively measured. The calculated values correlated well with the actual concentrations of cTnI. It is anticipated that the highly sensitive and selective aptasensor for cTnI could be readily applicable for the accurate diagnosis of AMI.

Манай facebook
хуудсанд нэгдээрэй

Шинжлэх ухаанаар баталгаажсан эмийн өвс ургамлын бүрэн мэдээллийн сан

  • 55 хэл дээр ажилладаг
  • Шинжлэх ухааны үндэслэсэн ургамлын гаралтай эдгэрэлт
  • Ургамлыг дүрсээр таних
  • Интерактив GPS газрын зураг - эмийн ургамлыг байршлаар нь тэмдэглэнэ (удахгүй)
  • Хайлттай холбоотой шинжлэх ухааны нийтлэлүүдийг уншина уу
  • Эмийн өвсийг үр нөлөөгөөр нь хайж олох
  • Мэдээллийн судалгаа, клиник туршилт, патентыг цаг тухайд нь сонирхож, зохион байгуул

Шинж тэмдэг эсвэл өвчний талаар бичиж, тус болох ургамлын талаар уншиж, өвслөг ургамлыг бичиж, өвчний эсрэг шинж тэмдгийг үзээрэй.
* Бүх мэдээлэл нь хэвлэгдсэн эрдэм шинжилгээний судалгаанд үндэслэсэн болно

Google Play badgeApp Store badge