Israel Medical Association Journal 2008-Oct

Is intraocular pressure in myotonic dystrophy patients spuriously low?

Alleen geregistreerde gebruikers kunnen artikelen vertalen
Log in Schrijf in
De link wordt op het klembord opgeslagen
Anat Kesler
Lior Berkner
Menachem Sadeh
Ronen Levite
David Varssano

Sleutelwoorden

Abstract

BACKGROUND

Ocular hypotony is a common unexplained feature of myotonic dystrophy type 1. Spuriously low applanation tonometric readings can be caused by thin corneas, flat corneal curvature and corneal edema.

OBJECTIVE

To determine whether structure abnormalities of the cornea cause spuriously low readings in applanation tonometry.

METHODS

We utilized a TMS-2N corneal topographer, a NonconRobo SP-6000 Specular microscope and a Corneo-Gage Plus 1A Pachymeter to examine seven patients with DM1 and eight healthy controls. Intraocular pressure, central corneal thickness, and endothelial cell density were measured, and simulated keratometry readings were made. Cornea guttata and irregularity of corneal topography patterns were also sought.

RESULTS

The mean intraocular pressure was 9.86 +/- 1.29 mmHg for all patients (intraocular operated and non-operated eyes) and 12.88 +/- 1.89 mmHg for the controls (P=0.000021, two-tailed t-test). Central corneal thickness was 530.57 +/- 35.30 micron for all patients and 535.00 +/- 39.62 micron for the controls (P=0.75, two-tailed t-test). Endothelial cell density was 3164 +/- 761 cells/ mm2 for all patients and 3148 +/- 395 cells/mm2 for the controls (P=0.94, two-tailed t-test). Simulated keratometry readings were similar in both groups when the operated eyes were excluded. Cornea guttata and irregularity of corneal topography patterns were also noted in the study group.

CONCLUSIONS

Corneal thickness, corneal curvature and corneal hydration were within normal limits and thus were not the cause for the low applanation tonometry reading in DM1. The presence of cornea guttata and irregularity of corneal topography patterns in DM1 warrants further investigation.

Word lid van onze
facebookpagina

De meest complete database met geneeskrachtige kruiden, ondersteund door de wetenschap

  • Werkt in 55 talen
  • Kruidengeneesmiddelen gesteund door de wetenschap
  • Kruidenherkenning door beeld
  • Interactieve GPS-kaart - tag kruiden op locatie (binnenkort beschikbaar)
  • Lees wetenschappelijke publicaties met betrekking tot uw zoekopdracht
  • Zoek medicinale kruiden op hun effecten
  • Organiseer uw interesses en blijf op de hoogte van nieuwsonderzoek, klinische onderzoeken en patenten

Typ een symptoom of een ziekte en lees over kruiden die kunnen helpen, typ een kruid en zie ziekten en symptomen waartegen het wordt gebruikt.
* Alle informatie is gebaseerd op gepubliceerd wetenschappelijk onderzoek

Google Play badgeApp Store badge