Dutch
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American Journal of Surgery 1999-Sep

Perigraft air, fever, and leukocytosis after endovascular repair of abdominal aortic aneurysms.

Alleen geregistreerde gebruikers kunnen artikelen vertalen
Log in Schrijf in
De link wordt op het klembord opgeslagen
O C Velázquez
J P Carpenter
R A Baum
C F Barker
M Golden
F Criado
A Pyeron
R M Fairman

Sleutelwoorden

Abstract

BACKGROUND

The postimplantation syndrome of fever and leukocytosis after endovascular repair of infrarenal aortic aneurysms has not been previously characterized and its etiology is not known.

METHODS

We studied the first 12 patients who underwent successful endovascular repair of infrarenal aortic aneurysms with Dacron-covered stent-grafts, as part of an ongoing phase II clinical trial. Sepsis syndrome evaluations (physical examination, urinalysis, chest radiograph, urine cultures, and blood cultures) were performed for all patients with postoperative temperature (T) greater than 101.4 degrees F. Computed tomography scans of the abdomen were performed, as part of the clinical protocol, on postoperative days 2 and 30.

RESULTS

Fever (T > 101.4 degrees F) was seen in 8 of 12 (67%) patients (P < 05). An additional 2 of 12 (17%) patients had low-grade fevers (100.3 degrees F, 100.6 degrees F). Only 2 of 12 (17%) patients remained afebrile postoperatively. Leukocytosis with counts over 11,000 white blood cells (WBC)/dL was observed in 7 of 12 (58%) patients (P < 05). Sepsis evaluations failed to identify any source of infection in 11 of 12 (97%) patients. Computed tomography scan evidence of perigraft air was noted in 8 of 12 (67%) patients. All patients were afebrile, had normal white blood cell counts, and were discharged within 1 week postoperatively. There has been no evidence of graft infection after 1 to 6 months of follow-up.

CONCLUSIONS

Fever and leukocytosis after stent-graft repair of aortic aneurysms does not represent evidence of systemic or graft infection and is not clearly related to nonspecific causes of postoperative fever and leukocytosis. Moreover, the finding of early postoperative perigraft air is not necessarily an indication of graft infection even when concurrently present with fever and leukocytosis.

Word lid van onze
facebookpagina

De meest complete database met geneeskrachtige kruiden, ondersteund door de wetenschap

  • Werkt in 55 talen
  • Kruidengeneesmiddelen gesteund door de wetenschap
  • Kruidenherkenning door beeld
  • Interactieve GPS-kaart - tag kruiden op locatie (binnenkort beschikbaar)
  • Lees wetenschappelijke publicaties met betrekking tot uw zoekopdracht
  • Zoek medicinale kruiden op hun effecten
  • Organiseer uw interesses en blijf op de hoogte van nieuwsonderzoek, klinische onderzoeken en patenten

Typ een symptoom of een ziekte en lees over kruiden die kunnen helpen, typ een kruid en zie ziekten en symptomen waartegen het wordt gebruikt.
* Alle informatie is gebaseerd op gepubliceerd wetenschappelijk onderzoek

Google Play badgeApp Store badge