Journal of Pediatrics 2015-Nov

Safety of Retinopathy of Prematurity Examination and Imaging in Premature Infants.

Alleen geregistreerde gebruikers kunnen artikelen vertalen
Log in Schrijf in
De link wordt op het klembord opgeslagen
Kelly C Wade
Maxwell Pistilli
Agnieshka Baumritter
Karen Karp
Alice Gong
Alex R Kemper
Gui-Shuang Ying
Graham Quinn
e-Retinopathy of Prematurity Study Cooperative Group

Sleutelwoorden

Abstract

OBJECTIVE

To describe adverse events (AEs) and noteworthy clinical or ocular findings associated with retinopathy of prematurity (ROP) evaluation procedures.

METHODS

Descriptive analysis of predefined AEs and noteworthy findings reported in a prospective observational cohort study of infants <1251 g birth weight who had ROP study visits consisting of both binocular indirect ophthalmoscopy (BIO) and digital retinal imaging. We compared infant characteristics during ROP visits with and without AEs. We compared respiratory support, nutrition, and number of apnea, bradycardia, or hypoxia events 12 hours before and after ROP visits.

RESULTS

A total of 1257 infants, mean birth weight 802 g, had 4263 BIO and 4048 imaging sessions (total 8311 procedures). No serious AEs were related to ROP visits. Sixty-five AEs were reported among 61 infants for an AE rate of 4.9% infants (61/1257) or 0.8% total procedures (65/8311 BIO + imaging). Most AEs were due to apnea, bradycardia, and/or hypoxia (68%), tachycardia (16%), or emesis (8%). At ROP visit, infants with AEs, compared with those without, were more likely to be on mechanical ventilation (26% vs 12%, P = .04) even after adjustment for weight and postmenstrual age. Noteworthy clinical findings were reported during 8% BIO and 15% imaging examinations. Respiratory and nutrition support were not significantly different before and after ROP evaluations.

CONCLUSIONS

Retinal imaging by nonphysicians combined with BIO was safe. Noteworthy clinical findings occurred during both procedures. Ventilator support was a risk factor for AEs. Monitoring rates of AEs and noteworthy findings are important to the safe implementation of ROP imaging protocols.

BACKGROUND

Clinicaltrials.gov: NCT01264276.

Word lid van onze
facebookpagina

De meest complete database met geneeskrachtige kruiden, ondersteund door de wetenschap

  • Werkt in 55 talen
  • Kruidengeneesmiddelen gesteund door de wetenschap
  • Kruidenherkenning door beeld
  • Interactieve GPS-kaart - tag kruiden op locatie (binnenkort beschikbaar)
  • Lees wetenschappelijke publicaties met betrekking tot uw zoekopdracht
  • Zoek medicinale kruiden op hun effecten
  • Organiseer uw interesses en blijf op de hoogte van nieuwsonderzoek, klinische onderzoeken en patenten

Typ een symptoom of een ziekte en lees over kruiden die kunnen helpen, typ een kruid en zie ziekten en symptomen waartegen het wordt gebruikt.
* Alle informatie is gebaseerd op gepubliceerd wetenschappelijk onderzoek

Google Play badgeApp Store badge