Norwegian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American Journal of Kidney Diseases 1985-Mar

Dialysis-induced hypoxemia: membrane dependent and membrane independent causes.

Bare registrerte brukere kan oversette artikler
Logg inn Registrer deg
Koblingen er lagret på utklippstavlen
G C Francos
A Besarab
J F Burke
J Peters
M V Tahamont
M H Gee
J T Flynn
D Gzesh

Nøkkelord

Abstrakt

Hypoxemia during hemodialysis may result from several differing processes. We initially studied patients undergoing standard acetate hemodialysis. At 15 minutes of dialysis, leukopenia (primarily neutropenia), a decline of platelet count, and hypoxemia occurred, but without a significant change in mean minute ventilation. Complement activation (V/A ratios of C5a greater than 1.0) persisted throughout dialysis. Leukocyte count returned to baseline by one hour. To separate the effects of solute and/or gas fluxes from those of blood-membrane interaction we studied changes in Po2, WBC, C5a, TxB2, and PGI2 during a period of blood membrane interaction without dialysis, and during subsequent acetate dialysis. Patients were studied with both polyacrylonitrile (PAN) and cuprophan membranes containing different priming solutions during membrane contact alone. Despite leukopenia and complement activation, hypoxemia failed to occur during membrane contact alone. At 15 minutes of subsequent acetate dialysis, significant hypoxemia occurred with both membranes. However, the degree of hypoxemia was twice as great with a cuprophan membrane primed with acetate (18.6 +/- 3.3 mm Hg) compared with air or bicarbonate (9.1 +/- 1.4 and 7.0 +/- 2.0 mm Hg, respectively), or compared with PAN (8 +/- 2.8 mm Hg). Changes in thromboxane B2, PGI2, and C5a did not correlate with changes in Po2. We conclude that there are two major components to dialysis related hypoxemia. One is membrane independent, and may relate to the metabolic effects of acetate or to dialyzer CO2 loss. The remaining portion is membrane dependent, occurring with cuprophan, but not with PAN, and is conditioned by an acetate dependent interaction between blood and membrane.

Bli med på
facebooksiden vår

Den mest komplette databasen med medisinske urter støttet av vitenskap

  • Fungerer på 55 språk
  • Urtekurer støttet av vitenskap
  • Urtegjenkjenning etter bilde
  • Interaktivt GPS-kart - merk urter på stedet (kommer snart)
  • Les vitenskapelige publikasjoner relatert til søket ditt
  • Søk medisinske urter etter deres effekter
  • Organiser dine interesser og hold deg oppdatert med nyheter, kliniske studier og patenter

Skriv inn et symptom eller en sykdom og les om urter som kan hjelpe, skriv en urt og se sykdommer og symptomer den brukes mot.
* All informasjon er basert på publisert vitenskapelig forskning

Google Play badgeApp Store badge