Norwegian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of rural medicine : JRM 2020-Apr

Methemoglobinemia due to local anesthesia: a rare cause of cyanosis and chest pain after placement of implantable cardioverter defibrillator.

Bare registrerte brukere kan oversette artikler
Logg inn Registrer deg
Koblingen er lagret på utklippstavlen
Yuksel Cicek
M Durakoglugil
Ece Usta

Nøkkelord

Abstrakt

Although methemoglobinemia is rare in adulthood, it may have fatal consequences if unnoticed. We planned to implant an implantable cardioverter defibrillator ICD in a 50-year-old male patient for primary prevention. Following sterile draping, prilocaine 5 mg/kg (400 mg) was injected subcutaneously for local anesthesia. We injected an additional dose of 200 mg due to pain during subclavian vein puncture. A DDD-R ICD was placed successfully within approximately 40 minutes. The patient complained of sudden chest pain and dyspnea 15 minutes after bed rest and was transferred to the coronary care unit due to cyanosis and deterioration of general status. Physical examination revealed blood pressure of 110/80 mmHg, pulse rate of 110 bpm, and otherwise unremarkable signs. Peripheral oxygen saturation was determined as 83% by pulse oximeter. Possible pneumothorax and cardiac perforation were excluded by emergency chest radiograph and echocardiography. Blood gas analyses was performed to assess for methemoglobinemia, which revealed pH 7.41, pCO2 40 mmHg, oxygen saturation 98.2%, and methemoglobin 7.9% that peaked to 12.3%. Methylene blue (1%) was slowly injected over 10 minutes at a dose of 1 mg/kg. Cyanosis waned and methemoglobin values decreased to 4.1%, 2.1%, and 1.1% at 2, 8, and 16 hours following the administration, respectively. The patient was safely discharged 2 days after implantation of pacemaker. Methemoglobinemia should be considered in cases presenting with cyanosis, non-diagnostic ECG, and a discrepancy in oxygen saturation between pulse oximetry and blood gas analyses.

Bli med på
facebooksiden vår

Den mest komplette databasen med medisinske urter støttet av vitenskap

  • Fungerer på 55 språk
  • Urtekurer støttet av vitenskap
  • Urtegjenkjenning etter bilde
  • Interaktivt GPS-kart - merk urter på stedet (kommer snart)
  • Les vitenskapelige publikasjoner relatert til søket ditt
  • Søk medisinske urter etter deres effekter
  • Organiser dine interesser og hold deg oppdatert med nyheter, kliniske studier og patenter

Skriv inn et symptom eller en sykdom og les om urter som kan hjelpe, skriv en urt og se sykdommer og symptomer den brukes mot.
* All informasjon er basert på publisert vitenskapelig forskning

Google Play badgeApp Store badge