Clinical Biochemistry 2015-Nov

Analytical evaluation of the novel soluble fms-like tyrosine kinase 1 and placental growth factor assays for the diagnosis of preeclampsia.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
Josef van Helden
Ralf Weiskirchen

Słowa kluczowe

Abstrakcyjny

OBJECTIVE

Performance evaluation of the novel BRAHMS KRYPTOR soluble fms-like tyrosine kinase 1 (sFlt-1) and placental growth factor (PlGF) assays.

METHODS

Intra- and inter-assay imprecision, functional sensitivity, linearity in dilution, method comparison, and diagnostic capacity were evaluated.

RESULTS

Intra-assay coefficient of variations (CVs) were between 1.1% and 5.3% and inter-assay CVs between 3.9% and 11.1%. Functional sensitivity was 6.7ng/L for PlGF and 34ng/L for sFlt-1, respectively. The linearity in dilution was excellent (r>0.995) in the assay-specific relevant range of concentration. The KRYPTOR assay correlated well with the Elecsys sFlt-1 (r=0.996), Elecsys PlGF (r=0.990) and the Elecsys sFlt-1/PlGF ratio (r=0.947) with partially high mean bias values. The optimal cut points for diagnosis of preeclampsia were calculated for KRYPTOR assays at: 60.5ng/L (PlGF), 4725ng/L (sFlt-1), and 99.2 (sFlt-1/PlGF ratio) which were different with the corresponding Elecsys cut points. Nevertheless, the sensitivity, specificity, positive predictive values (PPVs), negative predictive values (NPVs), and areas under the curves (AUCs) were completely comparable in both assay platforms, even when applying the standard cut-off of 85 for sFlt-1/PlGF ratio or gestational age specific "rule in-rule-out" cut-offs for early and late onset preeclampsia.

CONCLUSIONS

The new BRAHMS KRYPTOR sFlt-1 and PlGF immunoassay show excellent precision and reliability. The assay results and the diagnostic capacity were highly comparable to established fully automated immunoassays (Elecsys). Hence, sFlt-1/PlGF ratio generated on KRYPTOR immunoassay platform should be suitable for diagnosing preeclampsia in clinical routine laboratory.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge