Polish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Crohn's & colitis 2013-Jun

Diagnostic performance of Fluorine-18-Fluorodeoxyglucose positron emission tomography in patients with chronic inflammatory bowel disease: a systematic review and a meta-analysis.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
Giorgio Treglia
Natale Quartuccio
Ramin Sadeghi
Alessandra Farchione
Carmelo Caldarella
Francesco Bertagna
Piercarlo Fania
Angelina Cistaro

Słowa kluczowe

Abstrakcyjny

OBJECTIVE

To systematically review and meta-analyze published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in patients with chronic inflammatory bowel disease (IBD).

METHODS

A comprehensive computer literature search of studies published through May 2012 regarding (18)F-FDG-PET and PET/CT in patients with IBD was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odd ratio (DOR) of (18)F-FDG PET and PET/CT in patients with IBD on a per segment-based analysis were calculated. The area under the ROC curve was calculated to measure the accuracy of (18)F-FDG PET and PET/CT in patients with IBD.

RESULTS

Nineteen studies comprising 454 patients with suspected IBD were included in the qualitative analysis (systematic review) and discussed. The quantitative analysis (meta-analysis) of seven selected studies (including 219 patients with IBD) provided the following results on a per segment-based analysis: sensitivity was 85% [95% confidence interval (95%CI) 81-88%], specificity 87% (95%CI 84-90%), LR+ 6.19 (95%CI: 2.86-13.41), LR- 0.19 (95%CI: 0.10-0.34), and DOR 44.35 (95%CI: 11.77-167.07). The area under the ROC curve was 0.933.

CONCLUSIONS

In patients with suspected IBD (18)F-FDG PET and PET/CT demonstrated good sensitivity and specificity, being accurate methods in this setting. Nevertheless, the literature focusing on the use of PET and PET/CT in IBD remains still limited; thus, further large multicenter studies will be necessary to substantiate the diagnostic accuracy of these methods in patients with IBD.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge