Polish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Pediatric Radiology 2017-Mar

Focused CT using a height-adjusted metric and the umbilicus as a landmark for children undergoing evaluation for appendicitis.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
Suzanne Roberts
Abigail F Nixon
James A Meltzer
Einat Blumfield

Słowa kluczowe

Abstrakcyjny

BACKGROUND

Confirmation of appendicitis in children often requires CT. A focused CT scan that is limited to the lower abdomen/pelvis might help to reduce radiation exposure.

OBJECTIVE

To determine the position of the appendix relative to the umbilicus and derive a height-adjusted threshold for a focused CT that would identify most appendices.

METHODS

We conducted a retrospective study of children younger than 18 years who underwent a CT scan for suspected appendicitis. A pediatric radiologist determined the distance from the most cephalad portion of the appendix to the center of the umbilicus. This distance was divided by the child's height to create a ratio for each child. We then assessed the largest of these distance/height ratios ("height constants") as potential height-adjusted thresholds that, when multiplied by any patient's height, would yield the superior threshold for the focused CT scan. Radiation reduction was calculated as percentage decrease in scan length compared to a complete abdominopelvic CT.

RESULTS

Of 270 patients whose entire appendix was identified on CT, all were identified within 10.5 cm above the umbilicus. A focused CT using a height constant of 0.07 identified 100% of the appendices visualized on the complete CT scan and resulted in an estimated mean percentage radiation reduction of 27% (standard deviation [SD] +/-4.7). If a height constant of 0.03 was used, 97% of appendices were identified and the estimated radiation reduction was 43% (SD +/-4.3).

CONCLUSIONS

A height-adjusted focused abdominopelvic CT scan might reduce radiation exposure without sacrificing the diagnostic accuracy of the complete CT scan.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge