Polish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Eye and Contact Lens 2017-Jul

Influence of Apical Clearance on Mini-Scleral Lens Settling, Clinical Performance, and Corneal Thickness Changes.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
Fehim Esen
Ebru Toker

Słowa kluczowe

Abstrakcyjny

OBJECTIVE

The purpose of this work was to define the timing and magnitude of scleral contact lens settling, the factors influencing settling, and to examine whether the amount of apical clearance has an impact on clinical performance or is associated with hypoxia-induced corneal changes.

METHODS

Eleven patients (22 eyes) with keratoconus were fitted with a mini-scleral lens (Esclera, Brazil). Three different lenses with successively greater sagittal depths were applied to achieve 3 levels of initial apical clearance: 100 to 200 μm (low), 200 to 300 μm (medium), and greater than 300 μm (high). Corneal apical clearance was measured at 15 min, 1, 2, 4, 6, and 8 hr with optical coherence tomography (OCT). Central corneal thickness was measured with OCT and Pentacam, in the morning and immediately after removal of the contact lens.

RESULTS

Mean settling was 26.8±18.8 μm (42.7%) at 1 hr, 39.5±26.5 μm (62.9%) at 2 hr, 50.7±31.6 μm (80.8%) at 4 hr, 57.4±34.6 μm (91.4%) at 6 hr, and 62.8±38.4 μm (100%) at 8 hr. Settling rate was significantly lower in low apical clearance group (P=0.01). The smaller diameter lenses settled more (P=0.03). There was a slight statistically significant increase of 1.3% in central corneal thickness measured with OCT (P=0.03). Central corneal thickness measured with Pentacam at three locations increased slightly (P=0.001). Settling showed significant intrasubject and intersubject variations. The amount of corneal swelling and comfort scores did not differ significantly according to apical clearance.

CONCLUSIONS

The average amount of settling was 62.8 μm after 8 hr, 80% of which occurred during the first 4 hr. Slight corneal swelling (1.3%) occurred after 8 hr of wear.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge