International Journal of Radiation Oncology Biology Physics 1996-Feb

Local hyperthermia of N2/N3 cervical lymph node metastases: correlationof technical/thermal parameters and response.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
P Wust
H Stahl
K Dieckmann
S Scheller
J Löffel
H Riess
J Bier
V Jahnke
R Felix

Słowa kluczowe

Abstrakcyjny

OBJECTIVE

Patients with advanced head and neck carcinomas, primarily nonresectable as well as recurrent cases, were treated in multimodality regimens with radiotherapy, chemotherapy, and local hyperthermia. Commercially available microwave and radiowave applicators were used in 50 patients with N2/N3 cervical lymph node metastases during more than 250 heat treatments. To assess technical suitability, the achieved power densities and thermal parameters were tested for correlation with anatomical and geometrical factors. To assess effectiveness, the response was compared with derived parameters of the achieved temperature distributions.

METHODS

The temperature measurement points (in thermometry catheters) documented by computerized tomography are labeled according to tissue depth, shielding by osseous structures, and location in relation to the external applicators. Relative and absolute specific absorption rates (SAR) and cooling coefficients are extracted from the temperature-time curves. Time-averaged temperature-position curves are evaluated to obtain index temperatures (T90, T50, T20), minimum/maximum tumor temperatures, cumulative minutes T90 > or = 43 degrees C, and 43 degrees C-equivalent min T90. Radiation dose, treatment time, and chemotherapy regiment are also considered. A response parameter is defined using the pre- and posttherapeutic tumor volumes. A multivariate variance analysis is performed for the dependent variables power density, thermal parameters, and response.

RESULTS

A significant correlation exists between power density and absorption, presence of a fat layer, and applicator illumination. The maximum depth is 5 cm, where SAR of >= 10 mW/g are registered. Achieved temperatures at individual measurement points are dependent on the SAR, and to a lesser extent, the perfusion-dependent cooling coefficients, but the index temperature T90 is only significantly related to intratumorally achieved SAR. The thermal gradient (T20-T50) and temperature peak (T20) are significantly influenced by the tumor volume. The response is directly related to the index temperature T90, equivalent minute T90 43 degrees C, and cumulative minutes T90 > or = 40.5 degrees C, and inversely related to the tumor volume.

CONCLUSIONS

Local hyperthermia using microwave and radiowave applicators in the head and neck region is a tolerable and clinically practical supplementary therapy used as part of multimodal regimens, and has already been proven to be effective. However, the analyses also demonstrated the limits of currently available technology, and confirm the need for continued methodical research.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem