Polish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American Journal of Cardiology 2017-Jul

Predictors of Paravalvular Regurgitation After Implantation of the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Valve (from the REPRISE II Trial Extended Cohort).

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
Daniel J Blackman
Ian T Meredith
Nicolas Dumonteil
Didier Tchétché
David Hildick-Smith
Mark S Spence
Darren L Walters
Jan Harnek
Stephen G Worthley
Gilles Rioufol

Słowa kluczowe

Abstrakcyjny

Paravalvular leak (PVL) after transcatheter aortic valve replacement is associated with worse long-term outcomes. The Lotus Valve incorporates an innovative Adaptive Seal designed to minimize PVL. This analysis evaluated the incidence and predictors of PVL after implantation of the Lotus transcatheter aortic valve. The REPRISE II (REpositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System - Evaluation of Safety and Performance) Study With Extended Cohort enrolled 250 high-surgical risk patients with severe symptomatic aortic stenosis. Aortic regurgitation was assessed by echocardiography pre-procedure, at discharge and 30 days, by an independent core laboratory. Baseline and procedural predictors of mild or greater PVL at 30 days (or at discharge if 30-day data were not available) were determined using a multivariate regression model (n = 229). Of the 229 patients, 197 (86%) had no/trace PVL, 30 had mild, and 2 had moderate PVL; no patient had severe PVL. Significant predictors of mild/moderate PVL included device:annulus area ratio (odds ratio [OR] 0.87; 95% CI 0.83 to 0.92; p <0.001), left ventricular outflow tract calcium volume (OR 2.85; 95% CI 1.44 to 5.63; p = 0.003), and annulus area (OR 0.89; 95% CI 0.82 to 0.96; p = 0.002). When the device:annulus area ratio was <1, the rate of mild/moderate PVL was 53.1% (17 of 32). The rates of mild/moderate PVL with 0% to 5%, 5% to 10%, and >10% annular oversizing by area were 17.5% (11 of 63), 2.9% (2 of 70), and 3.2% (2 of 63), respectively. Significant independent predictors of PVL included device:annulus area ratio and left ventricular outflow tract calcium volume. When the prosthetic valve was oversized by ≥5%, the rate of mild or greater PVL was only 3%. In conclusion, the overall rates of PVL with the Lotus Valve are low and predominantly related to device/annulus areas and calcium; these findings have implications for optimal device sizing.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge