Medical Engineering and Physics 2000-May

Theoretical study of convergent ultrasound hyperthermia for treating bone tumors.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
B Y Lu
R S Yang
W L Lin
K S Cheng
C Y Wang
T S Kuo

Słowa kluczowe

Abstrakcyjny

This study investigates the optimal external parameters for using an ultrasound applicator for treating bone tumors. This system utilized spherically arranged applicators such as scanned focused ultrasound, and spherically focused multielement applicators. The power deposition pattern is modeled as geometric gain with exponential attenuation. The specific absorption rate ratio (SARR) criteria have been used to determine the proper heating domain of ultrasound driving frequency and therapeutic tumor diameter. The results demonstrate that the optimal driving frequency depends on tumor depth, ultrasound absorption of bone marrow, and diameter of bone, but it is independent of the acoustic window area and SARR. The treatable diameter of bone tumor increased when the absorption ratio of bone marrow to tumor, acoustic window of surface skin, and diameter of bone were elevated. However, the treatable diameter of bone tumor decreased when muscle thickness, SARR of bone tumor site to the surface skin, bone marrow, and bone declined. To deliver the ultrasound energy into the tumor site and to avoid the potential damage to the normal tissue as much as possible, the specific absorption rate (SAR) in the bone tumor site has to be three times higher than that in the surface skin, tumor/marrow, and marrow/bone interfaces. The temperature distributions can verify the SARR criteria in this model. This study provides the information for choosing the optimal operating frequency of the ultrasound transducer and the acoustic window on the skin surface, and for designing the ultrasound applicator for clinical implementation.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge