Portuguese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American Heart Journal 2000-Oct

Adequacy of intracoronary versus intravenous adenosine-induced maximal coronary hyperemia for fractional flow reserve measurements.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
A Jeremias
R J Whitbourn
S D Filardo
P J Fitzgerald
D J Cohen
E M Tuzcu
W D Anderson
A A Abizaid
G S Mintz
A C Yeung

Palavras-chave

Resumo

BACKGROUND

Fractional flow reserve (FFR) is a measure of coronary stenosis severity that is based on pressure measurements obtained at maximal hyperemia. The most widely used pharmacologic stimulus for maximal coronary hyperemia is adenosine, administered either as a continuous intravenous (IV) infusion or intracoronary (IC) bolus. IV adenosine has more side effects and is more costly than IC adenosine but has a more stable and prolonged hyperemic effect.

METHODS

We compared the efficacy of IC and IV adenosine administration for the measurement of FFR in a multicenter trial. Fifty-two patients with 60 lesions underwent determination of FFR with both IV and IC adenosine. IV adenosine was administered as a continuous infusion at a rate of 140 microgram/kg per minute until a steady state hyperemia was achieved. IC adenosine boluses were administered at a dose of 15 to 20 microgram in the right and 18 to 24 microgram in the left coronary artery. FFR was calculated as the ratio of the distal coronary pressure (from pressure guide wire) to the aortic pressure (guide catheter) at maximal hyperemia.

RESULTS

A total of 26 left anterior descending, 23 right, 9 left circumflex, and 3 left main coronary arteries were evaluated. Mean percent stenosis for both groups was 55.8% +/- 23.6% (range 0% to 95%), and mean FFR was 0.78 +/- 0.15 (range 0.41 to 0.98). There was a strong and linear correlation between FFR measurements with IV and IC adenosine (R = 0.978, y = 0. 032 + 0.964x, P <.001). The agreement between the 2 sets of measurements was also high, with a mean difference in FFR of -0.004 +/- 0.03. However, a small random scatter in both directions of FFR measurements was noted with 5 lesions (8.3%) where FFR with IC adenosine was higher by 0.05 or more compared with IV infusions, suggesting a suboptimal hyperemic response in these patients. Changes in heart rate and blood pressure were significantly higher with IV adenosine. Two patients with IV, but none with IC adenosine, had severe side effects (bronchospasm and severe nausea).

CONCLUSIONS

These results suggest that IC adenosine is equivalent to IV infusion for the determination of FFR in the majority of patients. However, in a small percentage of cases, coronary hyperemia was suboptimal with IC adenosine.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge