Gastrointestinal Endoscopy 2017-Jun

Electromagnetic-guided placement of nasoduodenal feeding tubes versus endoscopic placement: a randomized, multicenter trial.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
Wouter F W Kappelle
Daisy Walter
Paul H Stadhouders
Hendrik J A Jebbink
Frank P Vleggaar
Peter J van der Schaar
Jan Willem Kappelle
Ingeborg van der Tweel
Medard F M Van den Broek
Frank J Wessels

Palavras-chave

Resumo

OBJECTIVE

Electromagnetic-guided placement (EMP) of a nasoduodenal feeding tube by trained nurses is an attractive alternative to EGD-guided placement (EGDP). We aimed to compare EMP and EGDP in outpatients, ward patients, and critically ill patients with normal upper GI anatomy.

METHODS

In 3 centers with no prior experience in EMP, patients were randomized to placement of a single-lumen nasoduodenal feeding tube either with EGDP or EMP. The primary endpoint was post-pyloric position of the tube on abdominal radiography. Patients were followed for 10 days to assess patency and adverse events. The analyses were performed according to the intention-to-treat principle.

RESULTS

In total, 160 patients were randomized to EGDP (N = 76) or EMP (N = 84). Three patients withdrew informed consent, and no abdominal radiography was performed in 2 patients. Thus, 155 patients (59 intensive care unit, 38%) were included in the analyses. Rates of post-pyloric tube position between EGDP and EMP were comparable (79% vs 82%, odds ratio 1.16; 90% confidence interval, 0.58-2.38; P = .72). Adverse events were observed in 4 patients after EMP (hypoxia, GI blood loss, atrial fibrillation, abdominal pain) and in 4 after EGDP (epistaxis N = 2, GI blood loss, hypoxia). Costs of tube placements were lower for EMP compared with EGDP: $519.09 versus $622.49, respectively (P = .04).

CONCLUSIONS

Success rates and safety of EMP and EGDP in patients with normal upper GI anatomy were comparable. Lower costs and potential logistic advantages may drive centers to adopt EMP as their new standard of care. (Clinical trial registration number: NTR4286.).

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge