Portuguese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Biological Regulators and Homeostatic Agents

Exhaled breath condensate, nasal eosinophil cationic protein level and nasal cytology during immunotherapy for cypress allergy.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
M T Ventura
N Murgia
P Montuschi
M Gelardi
G Ciabattoni
R Buquicchio
O Resta
G Passalacqua

Palavras-chave

Resumo

Interest in cypress allergy is widely rising: an increasing number of studies have pointed out the efficacy of immunotherapy to reduce cypress-related symptoms and drug use. Cypress immunotherapy is well tolerated, but there are few studies dealing with its sub-clinical effects on the airways. The aim of this investigation is to assess the effects of immunotherapy on airways by the analysis of exhaled breath condensate (EBC), nasal lavage fluid (NAL) and nasal cytology. Fifteen mono-sensitized to cypress pollen patients have been observed, among them 9 have been treated with sub-cutaneous immunotherapy (SCIT), 3 with sub-lingual immunotherapy (SLIT) and 3 which were not treated underwent EBC, NAL and nasal cytology out of the pollen season. 8-isoprostane in EBC, Eosinophil cationic protein (ECP) and inflammatory cells in nasal cytology were also evaluated. The median value of 8-isoprostane in EBC was 18.58 pg/ml in patients who did not undergo immunotherapy, 49.38 pg/ml in SCIT patients and 13.41 pg/ml in SLIT subjects. The median value of ECP in nasal lavage was higher in non- treated subjects (27.3 mg/l) than in those treated with SCIT (1 mg/l)(p less than 0,05) or SLIT (2.6 mg/l). All nasal cytology specimens did not show any sign of inflammation. In conclusion SLIT seems to be well tolerated and to reduce significantly the levels of ECP in nasal lavage. In addition the levels of 8-isoprostane in EBC among SCIT patients were unexpectedly high and need to be further evaluated.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge