Portuguese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Nuclear Medicine Review 2019

Feasibility of myocardial perfusion imaging studies in morbidly obese patients with a cadmium-zinc-telluride cardiac camera.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
Anna Budzyńska
Sebastian Osiecki
Andrzej Mazurek
Stanisław Piszczek
Mirosław Dziuk

Palavras-chave

Resumo

A novel cardiac SPECT camera with cadmium-zinc-telluride (CZT) based technology has a fixed array of semiconductor detectors paired with pinhole collimators focused on the heart. Image acquisition in obese patients can be challenging because of much smaller detector field of view compared to conventional gamma cameras. The aim of this study was to evaluate the impact on high body mass on the feasibility of CZT myocardial perfusion imaging (MPI). The additional aim was to investigate the mechanism of the banana-shaped/obesity artifact, as referred to in literature, and to attempt at simulating it on a phantom study.Study group consisted of 43 patients with morbid obesity (BMI ≥ 40 kg/m2). All these patients underwent myocardial perfusion imaging on both CZT cardiac camera and general purpose SPECT/CT gamma camera. Control group consisted of all patients who underwent myocardial perfusion imaging on CZT camera throughout one calendar year and whose BMI was lower than 40 kg/m2. In this group, all repeated studies were re-analyzed for estimating the frequency of heart mispositioning in the camera field of view. The number of studies performed was 1180. A static cardiac phantom was used to simulate a banana-shaped artifact. A series of phantom acquisitions during which the phantom position was altered in the camera field of view was performed.In control group, 3.7% of all cardiac scintigrams required repetition, 18.9% of which were repeated due to wrong heart positioning; median BMI in this group of patients was 36.0. A banana-shaped artifact was observed in one female patient with BMI 36.0. In morbid obesity group, 32.6% of the studies were non-diagnostic with "truncation effect" on Scan Quality Control (QC). Median BMI in patients with diagnostic scans was 42.0, while in patients with not acceptable quality control test it was 45.0 (p < 0.05). Banana-shaped artifacts were observed in 5 non-diagnostic studies. In a phantom study an artifact of banana shape was obtained when gantry was distant from the phantom and target was on the edge of the camera field of view and was slightly truncated.Problem with heart mispositioning during imaging on the CZT camera affects less than 1% of all performed studies. Morbid obesity is not a contraindication to perform myocardia.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge