Radiologia Medica 2010-Feb

Low-dose unenhanced CT protocols according to individual body size for evaluating suspected renal colic: cumulative radiation exposures.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
S Tartari
R Rizzati
R Righi
A Deledda
S Terrani
G Benea

Palavras-chave

Resumo

OBJECTIVE

The aim of this study was to assess the radiation dose of dose-reduced unenhanced abdominal multidetector computed tomography (MDCT) scan protocols for suspected renal colic in patients within normal weight range and overweight-obese patients and to record the cumulative dose of repeated examinations.

METHODS

Over a 2-year period, we performed 1,026 unenhanced CT examinations for urolithiasis; among these, 675 were performed on 636 patients referred from the emergency department. Patients were divided into two groups on the basis of body mass index (BMI): normal weight (BMI <25 kg/m(2) group 1); overweight and obese (BMI >25 kg/m(2) group 2). For patients in group 1 and group 2, the protocols of our 64-row scanner prescribe tube current settings at 70 mAs and 150 mAs, respectively. The dose-length product (DLP) estimated by using the manufacturer's software was converted into effective dose (ED).

RESULTS

Mean DLP and ED were 177 and 345 mGy/cm and 2.4 and 4.8 mSv for group 1 and group 2, respectively. A subset of 25 patients (3.7%) underwent two or more examinations, with estimated ED ranging from 4.8 to 19.2 mSv.

CONCLUSIONS

Although radiation dose is nearly double in overweight-obese patients undergoing MDCT, it remains lower than that delivered by a standard-dose protocol. Patients with flank pain, who are often young, are at increased risk for serial CT examinations. Use of a low-dose protocol is mandatory in both normal-weight and obese patients to minimise radiation exposure.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge