Anesthesiology 2003-Oct

Pharmacokinetics of an implanted osmotic pump delivering sufentanil for the treatment of chronic pain.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
Dennis M Fisher
Norma Kellett
Rainer Lenhardt

Palavras-chave

Resumo

BACKGROUND

A matchstick-sized implanted osmotic pump (Chronogesic) that delivers sufentanil subcutaneously for more than 90 days is being developed to treat chronic pain. This study evaluates pharmacokinetic characteristics related to the absorption of sufentanil using a prototype 60-day system.

METHODS

Twelve opioid-naive volunteers were given naltrexone to prevent opioid effects. Sufentanil, 60 microg, was infused intravenously over 6 h, then 48 h later, the pump was implanted subcutaneously in the upper arm under local anesthesia. Pumps were removed 9 days later. In six volunteers, fever (1.6-3.3 degrees C) was induced with interleukin-2. Plasma was sampled and population pharmacokinetic modeling was performed to estimate in vivo release rate and absorption half-life. Bioavailability was calculated by comparing in vivo to in vitro release rates. The impact of perturbations in release rate on sufentanil plasma concentration (Cp) was simulated.

RESULTS

Fever had no systematic effect on Cp. Release rate estimated in vivo was similar to that measured in vitro; bioavailability did not differ from 100%. Absorption half-life was 16.2 h. Simulation demonstrated that supplemental release of sufentanil from the implant (as might occur with local heating) increases Cp an average of 2.5-2.8% per hours supplemental dose.

CONCLUSIONS

An implantable osmotic pump delivered sufentanil in vivo at the rate predicted from in vitro experiments. The rate at which sufentanil was absorbed from the subcutaneous space (half-life > 16 h) was markedly slower than reported with subcutaneous or intramuscular administration of large volumes of dilute opioids; this slow absorption dampens potential changes in Cp if release rate is perturbed.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge