Portuguese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Nuclear Medicine Communications 2004-Oct

Radioguided sentinel node detection in breast cancer patients: comparison of 99mTc phytate and 99mTc rhenium colloid efficacy.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
Mitsuru Koizumi
Etsuji Nomura
Yasuhiko Yamada
Tomohiro Takiguchi
Masujiro Makita
Takuji Iwase
Takashi Tada
Kei-ichiro Tada
Sei-ichiro Nishimura
Kaoru Takahashi

Palavras-chave

Resumo

BACKGROUND

Radioguided sentinel node biopsy (SNB) of breast cancer patients has become a standard method for detecting early stage breast cancer. However, no standard radiopharmaceutical exists.

METHODS

99mTc rhenium colloid or 99mTc phytate SNB was used to aid detection in breast cancer patients. For each radiopharmaceutical, 100 patients were examined. The following points were compared: (1) scintigraphic detection rate of axillary sentinel nodes (detectability and number when detectable) and internal mammary sentinel nodes; (2) the number of nodes detected scintigraphically and the number detected during surgery; (3) sensitivity, specificity, accuracy, negative predictive value, and positive predictive value for axillary sentinel nodes.

RESULTS

Axillary sentinel nodes of patients were biopsied using either 99mTc rhenium or 99mTc phytate. The number of axillary nodes surgically removed from patients given 99mTc rhenium was 2.28+/-1.08 (mean+/-SD), and the number of axillary nodes surgically removed from patients given 99mTc phytate was 1.68+/-0.82. Some patients given 99mTc rhenium showed a spill-over of radioactivity from sentinel nodes. Concordance of scintigraphically detected nodes and surgical removed nodes was superior for 99mTc phytate compared to that with 99mTc rhenium, with a statistically significant difference. The sensitivity and negative predictive value was superior with 99mTc phytate compared to that with 99mTc rhenium, even though no statistical difference was detectable. However, visualization of internal mammary nodes was superior with 99mTc rhenium.

CONCLUSIONS

In breast cancer patients, 99mTc phytate is a better choice for the detection of axillary SNB than 99mTc rhenium colloid. However, 99mTc rhenium colloid is a better choice for the detection of internal mammary nodes.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge