Journal of Heart and Lung Transplantation 2017-Jun

Risk factors, mortality, and timing of ischemic and hemorrhagic stroke with left ventricular assist devices.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
Jennifer A Frontera
Randall Starling
Sung-Min Cho
Amy S Nowacki
Ken Uchino
M Shazam Hussain
Maria Mountis
Nader Moazami

Palavras-chave

Resumo

BACKGROUND

Stroke is a major cause of mortality after left ventricular assist device (LVAD) placement.

METHODS

Prospectively collected data of patients with HeartMate II (n = 332) and HeartWare (n = 70) LVADs from October 21, 2004, to May 19, 2015, were reviewed. Predictors of early (during index hospitalization) and late (post-discharge) ischemic and hemorrhagic stroke and association of stroke subtypes with mortality were assessed.

RESULTS

Of 402 patients, 83 strokes occurred in 69 patients (17%; 0.14 events per patient-year [EPPY]): early ischemic stroke in 18/402 (4%; 0.03 EPPY), early hemorrhagic stroke in 11/402 (3%; 0.02 EPPY), late ischemic stroke in 25/402 (6%; 0.04 EPPY) and late hemorrhagic stroke in 29/402 (7%; 0.05 EPPY). Risk of stroke and death among patients with stroke was bimodal with highest risks immediately post-implant and increasing again 9-12 months later. Risk of death declined over time in patients without stroke. Modifiable stroke risk factors varied according to timing and stroke type, including tobacco use, bacteremia, pump thrombosis, pump infection, and hypertension (all p < 0.05). In multivariable analysis, early hemorrhagic stroke (adjusted odds ratio [aOR] 4.3, 95% confidence interval [CI] 1.0-17.8, p = 0.04), late ischemic stroke (aOR 3.2, 95% CI 1.1-9.0, p = 0.03), and late hemorrhagic stroke (aOR 3.7, 95% CI 1.5-9.2, p = 0.005) predicted death, whereas early ischemic stroke did not.

CONCLUSIONS

Stroke is a leading cause and predictor of death in patients with LVADs. Risk of stroke and death among patients with stroke is bimodal, with highest risk at time of implant and increasing risk again after 9-12 months. Management of modifiable risk factors may reduce stroke and mortality rates.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge