Portuguese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatographic Science 2014-Jul

Tailing of chromatographic peaks in GC-MS caused by interaction of halogenated solvents with the ion source.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
Jochen J Brocks
Janet M Hope

Palavras-chave

Resumo

The injection of analytes into a gas chromatography-mass spectrometry (GC-MS) system using dichloromethane (DCM) as solvent led to gradual deterioration of chromatographic signals, with significant tailing and loss of sensitivity for C17+ hydrocarbons. The injector, gas chromatograph and transfer line were excluded as causes. Normal peak shape could only be restored by the insertion of a cleaned MS ion source. To elucidate potential surficial contaminants, the ion source was heated from 260 to 320°C, leading to the release of increasing concentrations of ferrous chloride [FeCl2(g)]. The ferrous chloride probably formed through the decomposition of DCM on metal surfaces in the ion source. We posit that the tailing was caused by the adsorption of analytes to sub-µm layers of FeCl2 at crystal defect sites in the metal, followed by the slow release of molecules back into the gas phase. There are at least two other cases in the literature in which tailing is specifically associated with the use of halogenated solvents. However, it is possible that the problem is relatively common, albeit rarely diagnosed and reported. The tailing of chromatographic peaks caused by the formation of ferrous chloride in the mass spectrometer can be diagnosed by scanning the MS background signal for the diagnostic isotopic pattern of FeCl2(+). The problem is easily solved by cleaning the MS ion source and avoiding halogenated solvents.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge