European journal of nuclear medicine 2001-Nov

The use of (99m)Tc-phytate for sentinel node mapping in melanoma, breast cancer and vulvar cancer: a study of 100 cases.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
M G Tavares
M T Sapienza
N A Galeb
F A Belfort
R R Costa
C A Osório
J C Góes
I S Endo
J Soares
S Lewin

Palavras-chave

Resumo

Sentinel node mapping reduces surgical morbidity and allows the use of more accurate tumour staging techniques. Radionuclide studies are preferentially performed using small colloids, which have limited availability in our country. The possibility of using phytate for sentinel node mapping was raised because of the similarity between its biodistribution and that of nanocolloids in the reticulo-endothelial system. In this paper we evaluated the use of (99m)Tc-phytate for sentinel node mapping, correlating the histopathological results with the status of the rest of the lymph node chain in different malignant tumours. A total of 100 patients were studied. group 1 consisted of 62 patients with breast cancer, group 2 of 20 patients with melanoma and group 3 of 18 patients with vulvar carcinoma. Lymph node scintigraphy was carried out after injecting (99m)Tc-phytate subdermally, and the sentinel node projection was marked on the skin. After 18-24 h, intraoperative sentinel node localisation was performed using a gamma probe (combined with visual localisation using patent blue dye) in 75 patients, and lymph node dissection was then carried out. Radionuclide scintigraphy identified the sentinel node in 98% of all studies. Intraoperative detection using the gamma probe was equally efficient: group 1=93% (38/41), group 2=95% (18/19) and group 3=100% (15/15). The sentinel node was involved in 41%, 31% and 20% of cases in groups 1, 2 and 3, respectively. Among the patients with positive nodes, the sentinel node was the only one affected in 53% of group 1, 50% of group 2 and 67% of group 3 cases. The method's negative predictive value was 91% in group 1 and 100% in the other groups. One false-negative study occurred in a patient who had a multifocal tumour and an intraparenchymatous lymph node; another occurred in a patient with a macroscopically affected node found during surgery. There were no side-effects related to the (99m)Tc-phytate. It is concluded that scintigraphic and intraoperative sentinel node identification was satisfactorily performed using (99m)Tc-phytate. The results were comparable to those previously described in the literature using other radiopharmaceuticals. Easy availability and low cost justify the use of phytate in our practice.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge