Portuguese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Annals of Vascular Surgery 2016-Feb

Treatment of High Flow Arteriovenous Fistulas after Successful Renal Transplant Using a Simple Precision Banding Technique.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
Georgios Gkotsis
William C Jennings
Jan Malik
Alexandros Mallios
Kevin Taubman

Palavras-chave

Resumo

BACKGROUND

Observation versus ligation of a functional arteriovenous fistula (AVF) after successful renal transplantation (SRT) has been a controversial topic of debate. Congestive heart failure and pulmonary hypertension are common in dialysis patients, and more frequent when vascular access flow is excessive. Renal transplant failure may occur in up to 34% of patients after 5 years, therefore maintaining a moderate flow AVF appears warranted. We review SRT patients with high flow-AVFs (HF-AVF) and clinical signs of heart failure where a modified precision banding procedure was used for access flow reduction.

METHODS

Patients referred for HF-AVF evaluation after SRT were identified and records reviewed retrospectively. In addition to recording clinical signs of heart failure, each patient had ultrasound AVF flow measurement before and after temporary AVF occlusion of the access by digital compression. Pulse rate and the presence or absence of a cardiac murmur was noted before and after AVF compression. Adequacy of access flow restriction was evaluated intraoperatively using ultrasound flow measurements, adjusting the banding diameter in 0.5 mm increments to achieve the targeted AVF flow.

RESULTS

Twelve patients were evaluated over a 19-month period. Eight (66%) were male and one (8%) obese. Ages were 15-73 years (mean = 42). The AVFs were established 24-86 months previously. The mean pulse rate declined after AVF compression from 90/min to 72/min (range 110-78). Six patients had a precompression cardiac flow murmur that disappeared with temporary AVF compression. One patient with poor cardiac function underwent immediate AVF ligation with dramatic improvement in cardiac status. All other patients underwent a precision banding procedure with real-time flow monitoring. Mean access flow was 2,280 mL/min (1,148-3,320 mL/min) before access banding and was 598 mL/min (481-876) after flow reduction. The clinical signs of heart failure disappeared in all patients. All AVFs remained patent although one individual later requested ligation for cosmesis. Two patients had renal transplant failure and later successfully used the AVF. Follow-up postbanding was 1-18 months (mean = 12).

CONCLUSIONS

Patients with successful renal transplants and HF-AVFs had resolution of heart failure findings and maintenance of access patency using a modified precision banding procedure. Flow reduction in symptomatic renal transplant patients with elevated access flow is recommended. Further study is warranted to substantiate these recommendations and clarify the appropriate thresholds for such interventions.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge