Portuguese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of rural medicine : JRM 2020-Apr

Methemoglobinemia due to local anesthesia: a rare cause of cyanosis and chest pain after placement of implantable cardioverter defibrillator.

Apenas usuários registrados podem traduzir artigos
Entrar Inscrever-se
O link é salvo na área de transferência
Yuksel Cicek
M Durakoglugil
Ece Usta

Palavras-chave

Resumo

Although methemoglobinemia is rare in adulthood, it may have fatal consequences if unnoticed. We planned to implant an implantable cardioverter defibrillator ICD in a 50-year-old male patient for primary prevention. Following sterile draping, prilocaine 5 mg/kg (400 mg) was injected subcutaneously for local anesthesia. We injected an additional dose of 200 mg due to pain during subclavian vein puncture. A DDD-R ICD was placed successfully within approximately 40 minutes. The patient complained of sudden chest pain and dyspnea 15 minutes after bed rest and was transferred to the coronary care unit due to cyanosis and deterioration of general status. Physical examination revealed blood pressure of 110/80 mmHg, pulse rate of 110 bpm, and otherwise unremarkable signs. Peripheral oxygen saturation was determined as 83% by pulse oximeter. Possible pneumothorax and cardiac perforation were excluded by emergency chest radiograph and echocardiography. Blood gas analyses was performed to assess for methemoglobinemia, which revealed pH 7.41, pCO2 40 mmHg, oxygen saturation 98.2%, and methemoglobin 7.9% that peaked to 12.3%. Methylene blue (1%) was slowly injected over 10 minutes at a dose of 1 mg/kg. Cyanosis waned and methemoglobin values decreased to 4.1%, 2.1%, and 1.1% at 2, 8, and 16 hours following the administration, respectively. The patient was safely discharged 2 days after implantation of pacemaker. Methemoglobinemia should be considered in cases presenting with cyanosis, non-diagnostic ECG, and a discrepancy in oxygen saturation between pulse oximetry and blood gas analyses.

Junte-se à nossa
página do facebook

O mais completo banco de dados de ervas medicinais apoiado pela ciência

  • Funciona em 55 idiomas
  • Curas herbais apoiadas pela ciência
  • Reconhecimento de ervas por imagem
  • Mapa GPS interativo - marcar ervas no local (em breve)
  • Leia publicações científicas relacionadas à sua pesquisa
  • Pesquise ervas medicinais por seus efeitos
  • Organize seus interesses e mantenha-se atualizado com as notícias de pesquisa, testes clínicos e patentes

Digite um sintoma ou doença e leia sobre ervas que podem ajudar, digite uma erva e veja as doenças e sintomas contra os quais ela é usada.
* Todas as informações são baseadas em pesquisas científicas publicadas

Google Play badgeApp Store badge