Romanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Anaesthesia and Intensive Care 2014-Jan

Clarifying the role of activated charcoal filters in preparing an anaesthetic workstation for malignant hyperthermia-susceptible patients.

Numai utilizatorii înregistrați pot traduce articole
Log In / Înregistrare
Linkul este salvat în clipboard
J G Bilmen
R I Gillies

Cuvinte cheie

Abstract

Malignant hyperthermia (MH) is a life-threatening condition caused by exposure of susceptible individuals to volatile anaesthetics or suxamethonium. MH-susceptible individuals must avoid exposure to these drugs, so accurate and reproducible processes to remove residual anaesthetic agents from anaesthetic workstations are required. Activated charcoal filters (ACFs) have been used for this purpose. ACFs can reduce the time for preparing an anaesthetic workstation for MH patients. Currently, the only commercially available ACFs are the Vapor-Clean$trade; (Dynasthetics, Salt Lake City, UT, USA) filters which retail at approximately AUD$130 per set of two, both of which are to be used in a single anaesthetic. Anaesthetic workstations were saturated with anaesthetic vapours and connected to a Miran ambient air analyser (SapphRe XL, ThermoScientific, Waltham, MA, USA) to measure vapour concentration. Various scenarios were tested in order to determine the most economical configurations of machine flushing, component change and activated charcoal filter use. We found that placement of filters in an unprepared, saturated circuit was insufficient to safely prepare an anaesthetic workstation. Following flushing of the anaesthetic workstation with high-flow oxygen for 90 seconds, a circuit and soda lime canister change and the placement of an ACF on the inspiratory limb, we were able to safely prepare a workstation in less than three minutes. A single filter on the inspiratory limb was able to maintain a clean circuit for 12 hours, with gas flows dropped from 10 lpm to 3 lpm after 90 minutes or removal of the filter after 90 minutes if high gas flows were maintained.

Alăturați-vă paginii
noastre de facebook

Cea mai completă bază de date cu plante medicinale susținută de știință

  • Funcționează în 55 de limbi
  • Cure pe bază de plante susținute de știință
  • Recunoașterea ierburilor după imagine
  • Harta GPS interactivă - etichetați ierburile în locație (în curând)
  • Citiți publicațiile științifice legate de căutarea dvs.
  • Căutați plante medicinale după efectele lor
  • Organizați-vă interesele și rămâneți la curent cu noutățile de cercetare, studiile clinice și brevetele

Tastați un simptom sau o boală și citiți despre plante care ar putea ajuta, tastați o plantă și vedeți boli și simptome împotriva cărora este folosit.
* Toate informațiile se bazează pe cercetări științifice publicate

Google Play badgeApp Store badge