Romanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatographic Science 2014-Jul

Tailing of chromatographic peaks in GC-MS caused by interaction of halogenated solvents with the ion source.

Numai utilizatorii înregistrați pot traduce articole
Log In / Înregistrare
Linkul este salvat în clipboard
Jochen J Brocks
Janet M Hope

Cuvinte cheie

Abstract

The injection of analytes into a gas chromatography-mass spectrometry (GC-MS) system using dichloromethane (DCM) as solvent led to gradual deterioration of chromatographic signals, with significant tailing and loss of sensitivity for C17+ hydrocarbons. The injector, gas chromatograph and transfer line were excluded as causes. Normal peak shape could only be restored by the insertion of a cleaned MS ion source. To elucidate potential surficial contaminants, the ion source was heated from 260 to 320°C, leading to the release of increasing concentrations of ferrous chloride [FeCl2(g)]. The ferrous chloride probably formed through the decomposition of DCM on metal surfaces in the ion source. We posit that the tailing was caused by the adsorption of analytes to sub-µm layers of FeCl2 at crystal defect sites in the metal, followed by the slow release of molecules back into the gas phase. There are at least two other cases in the literature in which tailing is specifically associated with the use of halogenated solvents. However, it is possible that the problem is relatively common, albeit rarely diagnosed and reported. The tailing of chromatographic peaks caused by the formation of ferrous chloride in the mass spectrometer can be diagnosed by scanning the MS background signal for the diagnostic isotopic pattern of FeCl2(+). The problem is easily solved by cleaning the MS ion source and avoiding halogenated solvents.

Alăturați-vă paginii
noastre de facebook

Cea mai completă bază de date cu plante medicinale susținută de știință

  • Funcționează în 55 de limbi
  • Cure pe bază de plante susținute de știință
  • Recunoașterea ierburilor după imagine
  • Harta GPS interactivă - etichetați ierburile în locație (în curând)
  • Citiți publicațiile științifice legate de căutarea dvs.
  • Căutați plante medicinale după efectele lor
  • Organizați-vă interesele și rămâneți la curent cu noutățile de cercetare, studiile clinice și brevetele

Tastați un simptom sau o boală și citiți despre plante care ar putea ajuta, tastați o plantă și vedeți boli și simptome împotriva cărora este folosit.
* Toate informațiile se bazează pe cercetări științifice publicate

Google Play badgeApp Store badge