Journal of Pharmaceutical and Biomedical Analysis 2017-Apr

Quantification of EC-18, a synthetic monoacetyldiglyceride (1-palmitoyl-2-linoleoyl-3-acetyl-rac-glycerol), in rat and mouse plasma by liquid-chromatography/tandem mass spectrometry.

Только зарегистрированные пользователи могут переводить статьи
Войти Зарегистрироваться
Ссылка сохраняется в буфер обмена
Heon-Min Ryu
Yoo-Seong Jeong
Chang-Soon Yim
Jong-Hwa Lee
Suk-Jae Chung

Ключевые слова

абстрактный

EC-18 (i.e., 1-palmitoyl-2-linoleoyl-3-acetyl-rac-glycerol), an active ingredient in Rockpid®, has been reported to be useful in controlling various types of inflammations, particularly those caused by neutropenia. Although this product was originally approved as a functional food in Korea, it is currently in phase II clinical trials for use in managing the severe chemotherapy-induced neutropenia in patients with advanced breast cancer who are receiving intermediate febrile neutropenia risk chemotherapy. The objective of this study was to develop a rapid, sensitive method for the determination of EC-18 in rat and mouse plasma and to evaluate the applicability of the assay in pharmacokinetic studies. EC-18 was extracted with MeOH from rat and mouse plasma samples, and the extract directly introduced onto an LC-MS/MS system. The analyte and EC-18-d3, an internal standard, were analyzed by multiple reaction monitoring (MRM) at m/z transitions of 635.4→355.4 for EC-18 and 638.4→338.4 for the internal standard, respectively. The lower limit of quantification (LLOQ) was determined at 50ng/mL, with an acceptable linearity in the range from 50 to 10,000ng/mL (r>0.999) for both matrices. Validation parameters such as accuracy, precision, dilution, recovery, matrix effects and stability were found to be within the acceptance criteria of the assay validation guidelines, indicating that the assay is applicable for estimating EC-18 in concentrations in the range examined. EC-18 was readily determined in plasma samples for periods of up to 8h following an intravenous bolus injection of 1mg/kg in rats and at 5mg/kg in mice, respectively, and up to 24h following the oral administration of 2000mg/kg in mice. The findings indicate that the current analytical method is applicable for pharmacokinetic studies of EC-18 in small animals.

Присоединяйтесь к нашей
странице facebook

Самая полная база данных о лекарственных травах, подтвержденная наукой

  • Работает на 55 языках
  • Травяные лекарства, подтвержденные наукой
  • Распознавание трав по изображению
  • Интерактивная карта GPS - отметьте травы на месте (скоро)
  • Прочтите научные публикации, связанные с вашим поиском
  • Ищите лекарственные травы по их действию
  • Организуйте свои интересы и будьте в курсе новостей исследований, клинических испытаний и патентов

Введите симптом или заболевание и прочтите о травах, которые могут помочь, введите лекарство и узнайте о болезнях и симптомах, против которых оно применяется.
* Вся информация основана на опубликованных научных исследованиях.

Google Play badgeApp Store badge