Russian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Biosensors and Bioelectronics 2016-Dec

Quantification of the vascular endothelial growth factor with a bioluminescence resonance energy transfer (BRET) based single molecule biosensor.

Только зарегистрированные пользователи могут переводить статьи
Войти Зарегистрироваться
Ссылка сохраняется в буфер обмена
T Wimmer
B Lorenz
K Stieger

Ключевые слова

абстрактный

Neovascular pathologies in the eye like age-related macular degeneration (AMD), the diabetic retinopathie (DR), retinopathie of prematurity (ROP) or the retinal vein occlusion (RVO) are caused through a hypoxia induced upregulation of the vascular endothelial growth factor (VEGF). So far a correlation of intraocular VEGF concentrations to the impact of the pathologies is limited because of invasive sampling. Therefore, a minimally invasive, repeatable quantification of VEGF levels in the eye is needed to correlate the stage of VEGF induced pathologies as well as the efficacy of anti-VEGF treatment. Here we describe the development of three variants of enhanced BRET2 (eBRET2) based, single molecule biosensors by fusing a Renilla luciferase mutant with enhanced light output (RLuc8) to the N-terminus and a suitable eBRET2 acceptor fluorophore (GFP2) to the C-terminus of a VEGF binding domain, directly fused or separated with two different peptide linkers for the quantification of VEGF in vitro. The VEGF binding domain consists of a single chain variable fragment (scFv) based on ranibizumab in which the light- and the heavy- F(ab) chains were connected with a peptide linker to generate one open reading frame (orf). All three variants generate measureable eBRET2 ratios by transferring energy from the luciferase donor to the GFP2 acceptor, whereas only the directly fused and the proline variant permit VEGF quantification. The directly fused biosensor variant allows the quantification of VEGF with higher sensitivity, compared to the widely used ELISA systems and a wide dynamic quantification range in vitro. Our system demonstrates not only an additional in vitro application on VEGF quantification but also a promising step towards an applicable biosensor in an implantable device able to quantify VEGF reliably after implantation in vivo.

Присоединяйтесь к нашей
странице facebook

Самая полная база данных о лекарственных травах, подтвержденная наукой

  • Работает на 55 языках
  • Травяные лекарства, подтвержденные наукой
  • Распознавание трав по изображению
  • Интерактивная карта GPS - отметьте травы на месте (скоро)
  • Прочтите научные публикации, связанные с вашим поиском
  • Ищите лекарственные травы по их действию
  • Организуйте свои интересы и будьте в курсе новостей исследований, клинических испытаний и патентов

Введите симптом или заболевание и прочтите о травах, которые могут помочь, введите лекарство и узнайте о болезнях и симптомах, против которых оно применяется.
* Вся информация основана на опубликованных научных исследованиях.

Google Play badgeApp Store badge