Russian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Molecular Imaging and Biology 2013-Feb

Three-dimensional turbo-spin-echo amide proton transfer MR imaging at 3-Tesla and its application to high-grade human brain tumors.

Только зарегистрированные пользователи могут переводить статьи
Войти Зарегистрироваться
Ссылка сохраняется в буфер обмена
Xuna Zhao
Zhibo Wen
Ge Zhang
Fanheng Huang
Shilong Lu
Xianlong Wang
Shuguang Hu
Min Chen
Jinyuan Zhou

Ключевые слова

абстрактный

OBJECTIVE

Amide proton transfer (APT) imaging is able to extend the achievable magnetic resonance imaging (MRI) contrast to the protein level. In this study, we demonstrate the feasibility of applying a turbo-spin-echo (TSE)-based, three-dimensional (3D) APT sequence into routine clinical practice for patients with brain tumors.

METHODS

Experiments were performed on a Philips 3-Tesla (3-T) MRI scanner using an eight-channel phased-array coil for reception. A fast 3D APT sequence with a TSE acquisition was proposed (saturation power, 2 μT; saturation time, 500 ms; 8 slices). The gradient echo (GRE)-based field-mapping technique or water-saturation-shift-referencing (WASSR) technique was used to acquire B(0) maps to correct for B(0)-induced artifacts in APT images. The test was performed on a box of homogenous protein solution, four healthy volunteers, and eight patients with high-grade gliomas.

RESULTS

The experimental data from a homogenous, protein-containing phantom and healthy volunteers show that the sequence produced a uniform contrast across all slices. The average MTR(asym)(3.5 ppm) values with GRE B(0)-corrected 3D APT imaging and WASSR-corrected 3D APT imaging were both comparable to the values obtained using the undemanding single-slice acquisition. The average APT image intensity was consistently higher in the tumor core than in the peripheral edema and in the contralateral normal-appearing white matter (both P < 0.001).

CONCLUSIONS

3D APT imaging of brain tumors can be performed in about 5 min at 3-T using a routine, commercial eight-channel SENSE coil.

Присоединяйтесь к нашей
странице facebook

Самая полная база данных о лекарственных травах, подтвержденная наукой

  • Работает на 55 языках
  • Травяные лекарства, подтвержденные наукой
  • Распознавание трав по изображению
  • Интерактивная карта GPS - отметьте травы на месте (скоро)
  • Прочтите научные публикации, связанные с вашим поиском
  • Ищите лекарственные травы по их действию
  • Организуйте свои интересы и будьте в курсе новостей исследований, клинических испытаний и патентов

Введите симптом или заболевание и прочтите о травах, которые могут помочь, введите лекарство и узнайте о болезнях и симптомах, против которых оно применяется.
* Вся информация основана на опубликованных научных исследованиях.

Google Play badgeApp Store badge