Slovak
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Urology 1991-Sep

Conversion of the electrohydraulic electrode to an electromechanical stone impactor: basic studies and a case report.

Články môžu prekladať iba registrovaní používatelia
Prihlásiť Registrácia
Odkaz sa uloží do schránky
S P Dretler
K M Bhatta
D Rosen

Kľúčové slová

Abstrakt

A 3.3F electrohydraulic electrode (Wolf 2137.23) has been confined within a spring with a metal end cap, irrigated with water and covered with a 0.003-inch metal sheath (outside diameter 5F). The electrohydraulic lithotripsy discharge (Wolf Generator 2137.50) at E1 causes the metal cap to extend 3 mm. at 1,500 cm. per second and creates an impact pressure of 600 to 800 bar. Stone fragmentation efficiency of the electromechanical impactor was equivalent to unshielded electrohydraulic lithotripsy (gallstone 2.83 mg. per pulse, struvite/apatite 1.41 mg. per pulse, cystine 0.41 mg. per pulse, uric acid 1.48 mg. per pulse and 100% calcium oxalate monohydrate 0.10 mg. per pulse). Studies of the discharge of the electromechanical impactor within the pig ureter showed that minimal ureteral submucosal edema and hemorrhage occurred at 300 shocks discharged at a single point, and disruption of the mucosa and partial injury to the muscle layer occurred after 600 shocks given at the site of a pinched pig ureter. Pushing the electromechanical impactor perpendicular to the wall of the pig bladder will create a mechanical perforation within 35 shocks (electrohydraulic lithotripsy within 2 shocks). One patient had excellent fragmentation of a lower ureteral mixed monohydrate and dihydrate stone under direct vision performed with the electromechanical impactor passed via a 9.5F ureteroscope. There was no evidence of mucosal injury with 500 shocks. The electromechanical impactor has been developed to provide a safe and inexpensive method of ureteral stone fragmentation or disimpaction. These studies were performed to establish limits of safety that may allow use of the electromechanical impactor for stone fragmentation in the ureter without the need for ureteroscopy.

Pripojte sa k našej
facebookovej stránke

Najkompletnejšia databáza liečivých bylín podporovaná vedou

  • Pracuje v 55 jazykoch
  • Bylinné lieky podporené vedou
  • Rozpoznávanie bylín podľa obrázka
  • Interaktívna GPS mapa - označte byliny na mieste (už čoskoro)
  • Prečítajte si vedecké publikácie týkajúce sa vášho hľadania
  • Vyhľadajte liečivé byliny podľa ich účinkov
  • Usporiadajte svoje záujmy a držte krok s novinkami, klinickými skúškami a patentmi

Zadajte príznak alebo chorobu a prečítajte si o bylinách, ktoré by vám mohli pomôcť, napíšte bylinu a pozrite sa na choroby a príznaky, proti ktorým sa používa.
* Všetky informácie sú založené na publikovanom vedeckom výskume

Google Play badgeApp Store badge