Slovak
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Seminars in Thrombosis and Hemostasis 2013-Apr

Interference in coagulation testing: focus on spurious hemolysis, icterus, and lipemia.

Články môžu prekladať iba registrovaní používatelia
Prihlásiť Registrácia
Odkaz sa uloží do schránky
Giuseppe Lippi
Mario Plebani
Emmanuel J Favaloro

Kľúčové slová

Abstrakt

The chance that errors might jeopardize the quality of testing is inherently present throughout the total testing process, especially in the preanalytical phase. In the coagulation laboratory, as well as in other areas of diagnostic testing, spurious hemolysis, icteria, and lipemia in test samples represent by far the leading diagnostic challenges. Interference in hemostasis testing due to spurious hemolysis is attributed to both analytical and biologic elements, namely high absorbance of cell-free hemoglobin at wavelengths used by optical instrumentation and release of both cytoplasmatic and plasma membrane molecules (e.g., tissue factor, proteases, phospholipids, and ADP) that can spuriously activate blood coagulation and platelets. The interference attributable to hyperbilirubinemia is mostly due to spectral overlap, whereas that of hypertriglyceridemia mainly reflects elements of light scatter and volume displacement as well as direct interference of lipid particles with hemostasis. In practical terms, spurious hemolysis reflects a more generalized process of endothelial and blood cell damage, so that test results on spuriously hemolyzed specimens should be systematically suppressed. The bias attributable to hyperbilirubinemia is less significant using modern coagulometers equipped with dedicated wavelengths (i.e., with readings at 650 nm or above), so that test results in samples with a bilirubin concentration up to 20 mg/dL can still be analytically reliable. The interference observed in lipemic samples is most evident with readings using wavelengths lower than 500 nm and can hence be prevented with readings at 650 nm or above, and/or using higher dilutions of the test sample, or can be abated in high hypertriglyceridemic specimens (i.e., > 1,000 mg/dL) using high speed microcentrifugation or lipid extraction with organic solvents such as fluorine-chlorinated hydrocarbon, or lipid-clearing agents such as LipoClear (StatSpin Inc., Norwood, MA) and n-hexane.

Pripojte sa k našej
facebookovej stránke

Najkompletnejšia databáza liečivých bylín podporovaná vedou

  • Pracuje v 55 jazykoch
  • Bylinné lieky podporené vedou
  • Rozpoznávanie bylín podľa obrázka
  • Interaktívna GPS mapa - označte byliny na mieste (už čoskoro)
  • Prečítajte si vedecké publikácie týkajúce sa vášho hľadania
  • Vyhľadajte liečivé byliny podľa ich účinkov
  • Usporiadajte svoje záujmy a držte krok s novinkami, klinickými skúškami a patentmi

Zadajte príznak alebo chorobu a prečítajte si o bylinách, ktoré by vám mohli pomôcť, napíšte bylinu a pozrite sa na choroby a príznaky, proti ktorým sa používa.
* Všetky informácie sú založené na publikovanom vedeckom výskume

Google Play badgeApp Store badge