Slovak
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine 2002

Performance of large- and small-volume valved holding chambers with a new combination long-term bronchodilator/anti-inflammatory formulation delivered by pressurized metered dose inhaler.

Články môžu prekladať iba registrovaní používatelia
Prihlásiť Registrácia
Odkaz sa uloží do schránky
Mark W Nagel
Kimberly J Wiersema
Sara-Lou Bates
Jolyon P Mitchell

Kľúčové slová

Abstrakt

The treatment of both the bronchoconstriction and inflammatory aspects of asthma simultaneously by a single pressurized metered dose inhaler (pMDI) represents a significant advance in convenience to the patient. However, a valved holding chamber (VHC) may still be needed to reduce the coarse component of the dose that is likely to deposit in the oropharyngeal region, and a small sized device may offer significant advantages to the patient from the standpoint of compliance with therapy. VHCs representing small (adult AeroChamber Plus with mouthpiece, 149-mL) and large (Volumatic, 750-mL) devices have been compared in an in vitro evaluation with Seretide/Advair (hydro-fluoro alkane [HFA]-formulated fluticasone propionate [FP = 125 microg/dose] and salmeterol xinafoate [SX = 25 microg/dose]) by Andersen Mark-II eight-stage impactor operated at 28.3 L/min following compendial methodology. Fine particle fraction, based on the size range from 1.1 to 4.7 microm aerodynamic diameter, from either large or small VHCs with either component (69-79%) was similar [p > or = 0.08], and significantly greater than that from the pMDI alone (approximately 40%) [p < 0.001]. Fine particle dose emitted by the VHCs for SX (8.2 +/- 0.8 microg for the AeroChamber Plus and 7.7 +/- 0.5 microg for the Volumatic) were comparable, and also similar to the fine particle dose delivered by the pMDI when used without a VHC (7.6 +/- 0.6 microg). Fine particle doses for the FP component delivered by the two VHCs (46.4 +/- 3.4 microg for the AeroChamber Plus and 46.3 +/- 2.7 microg for the Volumatic) were equivalent, but were slightly greater than the corresponding fine particle dose from the pMDI alone (39.1 +/- 2.6 microg). However, this difference (approximately 20%) is close to the limit of resolution based on intermeasurement variability and is unlikely to have clinical significance, given the interpatient variability seen with inhaled drug therapy. It is therefore concluded that either of these VHCs has equivalent in vitro performance with this combination formulation in terms of the portion of the dose emitted from the pMDI that is likely to reach the receptors in the lungs.

Pripojte sa k našej
facebookovej stránke

Najkompletnejšia databáza liečivých bylín podporovaná vedou

  • Pracuje v 55 jazykoch
  • Bylinné lieky podporené vedou
  • Rozpoznávanie bylín podľa obrázka
  • Interaktívna GPS mapa - označte byliny na mieste (už čoskoro)
  • Prečítajte si vedecké publikácie týkajúce sa vášho hľadania
  • Vyhľadajte liečivé byliny podľa ich účinkov
  • Usporiadajte svoje záujmy a držte krok s novinkami, klinickými skúškami a patentmi

Zadajte príznak alebo chorobu a prečítajte si o bylinách, ktoré by vám mohli pomôcť, napíšte bylinu a pozrite sa na choroby a príznaky, proti ktorým sa používa.
* Všetky informácie sú založené na publikovanom vedeckom výskume

Google Play badgeApp Store badge