Slovak
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Clinical Laboratory Analysis 1992

User-defined serum aspartate and alanine aminotransferase, cholesterol, triglycerides, urea, and uric acid for the Beckman synchron CX 4/5 using Ames Sera-Pak reagents.

Články môžu prekladať iba registrovaní používatelia
Prihlásiť Registrácia
Odkaz sa uloží do schránky
P H Lolekha
P Nitipaichit

Kľúčové slová

Abstrakt

Beckman aspartate aminotransferase (AST), alanine aminotransferase (ALT), cholesterol, triglycerides, urea, and uric acid Liquid Reagents for Synchron CX 4/5 (48, 48, 25, 60, 26, and 30 cents US/test, respectively) are expensive. We have established our own methods for serum AST, ALT, cholesterol, triglycerides, urea, and uric acid (6, 6, 5, 12, 13, and 6 cents US/test, respectively) using Ames Sera-Pak reagents. Linearity of our AST, ALT, cholesterol, triglycerides, urea, and uric acid methods were either similar to or higher than the Beckman methods. The within run and day-to-day run precisions were acceptable. Recovery of our AST, ALT, cholesterol, triglycerides, urea, and uric acid were excellent. Our results for AST, ALT, cholesterol, triglycerides, urea, and uric acid correlated well with the Beckman results. Bilirubin (340.8 mumol/L) did not significantly interfere on our AST, ALT, cholesterol, triglycerides, and urea, while its concentrations of 165.8 mumol/L started giving negative interference on uric acid. Turbidity (2+) did not interfere significantly on our AST and ALT but started giving positive interference on cholesterol, triglycerides, urea, and uric acid. Hemolysis (2+) gave positive interference on our cholesterol, triglycerides, urea, and uric acid. Stability of Ames Sera-Pak working reagents was at least 30 days for AST, ALT, urea, and uric acid and 40 days for cholesterol and triglycerides.

Pripojte sa k našej
facebookovej stránke

Najkompletnejšia databáza liečivých bylín podporovaná vedou

  • Pracuje v 55 jazykoch
  • Bylinné lieky podporené vedou
  • Rozpoznávanie bylín podľa obrázka
  • Interaktívna GPS mapa - označte byliny na mieste (už čoskoro)
  • Prečítajte si vedecké publikácie týkajúce sa vášho hľadania
  • Vyhľadajte liečivé byliny podľa ich účinkov
  • Usporiadajte svoje záujmy a držte krok s novinkami, klinickými skúškami a patentmi

Zadajte príznak alebo chorobu a prečítajte si o bylinách, ktoré by vám mohli pomôcť, napíšte bylinu a pozrite sa na choroby a príznaky, proti ktorým sa používa.
* Všetky informácie sú založené na publikovanom vedeckom výskume

Google Play badgeApp Store badge