International journal of cell cloning 1984-May

Evaluation of an automated image analysis system for counting human tumor colonies.

Samo registrirani uporabniki lahko prevajajo članke
Prijava / prijava
Povezava se shrani v odložišče
S E Salmon
L Young
J Lebowitz
S Thomson
J Einsphar
T Tong
T E Moon

Ključne besede

Povzetek

The Omnicon FAS II image analysis system was applied to counting tumor colonies grown in a soft agar human tumor clonogenic assay with a detailed protocol designed to assess the instrument's sensitivity, specificity, precision, and accuracy. Comparisons of technician and instrument counts were done on a blinded basis. Sensitivity studies (which used metal microspheres) yielded a correlation coefficient (r) of 0.999 between technicians and the counter. A field-by-field analysis of the instrument's specificity for identifying individual objects correctly as tumor colonies rather than artifacts (as identified by the technician) was excellent (r = 0.95). In the precision studies (determined with repeated automated counting of the same samples for five days), the median coefficient of variation was less than 7%. Accuracy was evaluated on cultures of fresh biopsies from 30 human cancers obtained for drug sensitivity testing as well as on a series of tumor cell lines. The correlation between the mean number of colonies counted by the technicians and by the colony counter was greater than 0.91. Similar comparisons of mean percent survival of tumor colony-forming cells after drug exposure between technician and machine were also quite acceptable (r = 0.85). We conclude that the colony counter provided sufficient reliability to be applied to counting human tumor colonies grown in vitro. In addition, the colony counter performed the Petri dish counts ten times faster than experienced technicians and without associated operator fatigue.

Pridružite se naši
facebook strani

Najbolj popolna baza zdravilnih zelišč, podprta z znanostjo

  • Deluje v 55 jezikih
  • Zeliščna zdravila, podprta z znanostjo
  • Prepoznavanje zelišč po sliki
  • Interaktivni GPS zemljevid - označite zelišča na lokaciji (kmalu)
  • Preberite znanstvene publikacije, povezane z vašim iskanjem
  • Iščite zdravilna zelišča po njihovih učinkih
  • Organizirajte svoje interese in bodite na tekočem z raziskavami novic, kliničnimi preskušanji in patenti

Vnesite simptom ali bolezen in preberite o zeliščih, ki bi lahko pomagala, vnesite zelišče in si oglejte bolezni in simptome, proti katerim se uporablja.
* Vse informacije temeljijo na objavljenih znanstvenih raziskavah

Google Play badgeApp Store badge