Slovenian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography A 2005-Oct

Orthogonal array designs for the optimization of liquid-liquid-liquid microextraction of nonsteroidal anti-inflammatory drugs combined with high-performance liquid chromatography-ultraviolet detection.

Samo registrirani uporabniki lahko prevajajo članke
Prijava / prijava
Povezava se shrani v odložišče
Jingming Wu
Hian Kee Lee

Ključne besede

Povzetek

Orthogonal array designs (OADs) were applied for the first time to optimize liquid-liquid-liquid microextraction (LLLME) conditions for the analysis of three nonsteroidal anti-inflammatory drug residues (2-(4-chlorophenoxy)-2-methylpropionic acid, ketoprofen, and naproxen) in wastewater samples. Six relevant factors were investigated: type of organic solvent, composition of donor phase and acceptor phase, stirring speed, extraction time and salt concentration. In the first stage, mixed-level orthogonal array design, an OA16 (4(1) x 2(12)) matrix was employed to study the effect of six factors, by which the effect of each factor was estimated using individual contributions as response functions. Based on the results of the first stage, 1-octanol was chosen as organic solvent for extraction. The other five factors were selected for further optimization using an OA16 (4(5)) matrix and a 4 x 4 table to locate more exact levels for each variable. The relative standard deviations for the reproducibility of optimized LLLME varied from 6.2 to 7.1%. The coefficients of determination for calibration curves were higher than 0.9950. The method detection limits for drugs spiked in ultrapure water were in the range of 0.03-0.3 ng/mL. The final optimized conditions were applied to the analysis of drug residues in three wastewater samples in Singapore.

Pridružite se naši
facebook strani

Najbolj popolna baza zdravilnih zelišč, podprta z znanostjo

  • Deluje v 55 jezikih
  • Zeliščna zdravila, podprta z znanostjo
  • Prepoznavanje zelišč po sliki
  • Interaktivni GPS zemljevid - označite zelišča na lokaciji (kmalu)
  • Preberite znanstvene publikacije, povezane z vašim iskanjem
  • Iščite zdravilna zelišča po njihovih učinkih
  • Organizirajte svoje interese in bodite na tekočem z raziskavami novic, kliničnimi preskušanji in patenti

Vnesite simptom ali bolezen in preberite o zeliščih, ki bi lahko pomagala, vnesite zelišče in si oglejte bolezni in simptome, proti katerim se uporablja.
* Vse informacije temeljijo na objavljenih znanstvenih raziskavah

Google Play badgeApp Store badge