Albanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 2005-Sep

Determination of lorazepam in plasma from children by high-performance liquid chromatography with UV detection.

Vetëm përdoruesit e regjistruar mund të përkthejnë artikuj
Identifikohuni Regjistrohu
Lidhja ruhet në kujtesën e fragmenteve
Simon N Muchohi
Kenneth Obiero
Gilbert O Kokwaro
Bernhards R Ogutu
Isaiah M Githiga
Geoffrey Edwards
Charles R J C Newton

Fjalë kyçe

Abstrakt

A simple, sensitive, selective, and reproducible reversed-phase high-performance liquid chromatographic (HPLC) method with UV detection was developed for the determination of lorazepam (LZP) in human plasma, using oxazepam (OZP) as internal standard. LZP and OZP were extracted from alkalinized (pH 9.5) spiked and clinical plasma samples using a single step liquid-liquid extraction with a mixture of n-hexane-dichloromethane (70:30%; v/v). Chromatographic separation was performed on a reversed-phase Synergi Max RP analytical column (150 mmx4.6 mm i.d.; 4 microm particle size), using an aqueous mobile phase (10 mM KH2PO4 buffer (pH 2.4)-acetonitrile; 65:35%, v/v) delivered at a flow-rate of 2.5 ml/min. Retention times for OZP and LZP were 10.2 and 11.9 min, respectively. Calibration curves were linear from 10 to 300 ng with correlation coefficients (r2) better than 0.99. The limits of detection (LOD) and quantification (LOQ) were 2.5 and 10 ng/ml, respectively, using 0.5 ml samples. The mean relative recoveries at 20 and 300 ng/ml were 84.1+/-5.5% (n=6) and 72.4+/-5.9% (n=7), respectively; for OZP at 200 ng the value was 68.2+/-6.8% (n=14). The intra-assay relative standard deviations (R.S.D.) at 20, 150 and 270 ng/ml of LZP were 7.8%, 9.8% (n=7 in all cases) and 6.6% (n=8), respectively. The inter-assay R.S.D. at the above concentrations were 15.9%, 7.7% and 8.4% (n=7 in all cases), respectively. Intra- and inter-assay accuracy data were within the acceptance interval of +/-20% of the nominal values. There was no interference from other commonly co-administered anticonvulsant, antimicrobial, antipyretic, and antimalarial drugs. The method has been successfully applied to a pharmacokinetic study of LZP in children with severe malaria and convulsions following administration of a single intravenous dose (0.1 mg/kg body weight) of LZP.

Bashkohuni në faqen
tonë në facebook

Baza e të dhënave më e plotë e bimëve medicinale e mbështetur nga shkenca

  • Punon në 55 gjuhë
  • Kurime bimore të mbështetura nga shkenca
  • Njohja e bimëve nga imazhi
  • Harta GPS interaktive - etiketoni bimët në vendndodhje (së shpejti)
  • Lexoni botime shkencore në lidhje me kërkimin tuaj
  • Kërkoni bimë medicinale nga efektet e tyre
  • Organizoni interesat tuaja dhe qëndroni në azhurnim me kërkimet e lajmeve, provat klinike dhe patentat

Shkruani një simptomë ose një sëmundje dhe lexoni në lidhje me barërat që mund të ndihmojnë, shtypni një barishte dhe shikoni sëmundjet dhe simptomat që përdoren kundër.
* I gjithë informacioni bazohet në kërkimin shkencor të botuar

Google Play badgeApp Store badge